Check to ensure that the rotor (5) can turn around.
Replace the pump housing (3) on the motor (9) and then secure evenly
using the pumping house screws (8).
Place the motor (9) with the pump housing (3) back into the shaft (10).
Replace the non-return ring (11) and fix them in place using the screws
(12).
Place the suction basket (2) back on the pump housing (3) if the suction
basket (2) is being used.
Once everything is assembled, the pump can be switched on again.
Maintenance
To ensure a long life and problem-free operation, we recommend that you
maintain and clean your pump regularly. Maintenance work can be carried out by
anyone with very little effort, see also assembly/dismantling.
Time intervals:
In the beginning, you can check that the pump is working properly every
day. Clean the pump as set out above.
The regularity with which you clean the pump depends on the extent to
which the water is contaminated.
Check during maintenance to see if there has been any wear and tear or if parts
are worn or damaged. Replace any parts that are worn or damaged. Check the
list of replacement parts for this purpose.
Important: If you have hard water
in your area, it is useful to regularly clean the rotor (5) and the interior
of the motor (9).
Parts list:
(figure 7)
Provide the drawing number, the description and the pump type when ordering.
Parts that can be ordered from your dealer.
Winter period
Protect the pump against freezing during winter; if necessary, pump the
water out of the system or remove the pump from the water.
Clean the pump as described earlier, before putting it in storage.
Place the pump in a water container at a frost-free location to prevent
the rubber seals from drying out.
No. Description
1
Logo plate
2
Suction basket
3
Pump housing
4
O-ring
5
Rotor
6
Bearing
7
Bearing holder
8
Pump housing screws
9
Motor
No. Description
10
Foot
11
Non-return ring
12
Screws
13
VarioFlowControl panel
14
Hose fitting seal
15
Hose fitting
16
Nut
17
Adhesive connection seal
18
Adhesive connection
English