TD- Documentation
Page 10 of 68 219-100-0-0-1.0.doc
Mounting Instruction
Chain drive KSA xxx-24 V / 230V
Suitability of application for
windows / flaps in roof area
For the different drive contact points
on the casement the following must be
considered:
Total weight of casement
(glass + frame)
Size of casement
outer width of casement (FAB) x outer height of casement (FAH)
Snow load
(depending on snow load zone / application area)
Slope of roof
(important for calculating snow load)
Wind load
(influence of side winds)
Required opening cross section
(geometric or aerodynamic)
Required force and stroke of drive(s)
There are very many different kinds of window profile systems on the market.
Different mounting brackets and fastening devices to be used depend on the particular profile.
On the pages below you may find special planning details for prevalent systems.
The request for separate planning diagrams is optional.
4
Roof window systems
Pyramid
Light dome
Top hung
Bottom hung
Single direct (HSK-RA)
Single direct (HSK-FL)
Single direct (HSK-RA)
Single direct (HSK-RA)
Tandem sideways (NSK-RA) Tandem sideways (NSK-RA)
Tandem sideways (NSK-RA)
Tandem direct (HSK-RA)
Tandem direct (HSK-RA)
Single/Tandem direct (HSK)
Tandem sideways (NSK-RA)
General range of casement dimensions
Single contact directly on HSK
Tandem contact directly on HSK
Tandem contact sideways on NSK
Outside dimensions of FAB / FAH in mm
Other dimensions upon request
Tandem sideways (NSK-RA)
1,
35
m
1,
35
m
Symbols explanation
very
suitable
not so
suitable
doubtful
application