Inside the Control Center after back housing is
removed, you can find the DIP switch. These three
switches are used to control the span and heat/cool
system. Set the DIP switch (position 3) according
to
your selection of heater system or cooler system
as the
following diagram.
Set the DIP switch (position 3)
3.2)
Temperature Span Selection
Span is the temperature difference between the
turn
on temperature and turn off temperature. For
example,
in heating system, if you set temperature
to 20°C
and span to 1°C, the heater will operate
when the
room temperature drops to 19.5°C and
turns off when
the temperature rises to 20.5°C. Set
the DIP switch
(position 1 & 2) according to your
selection of temperature
span as the following
diagram.
ARATON 2100 TX
11
On: Heater
Off: Cooler
1
2
ON
SPAN
1
°C
2°C
3°C
4°C
ON
ON
1
1
2
2
3
3
ON
ON
ON
OFF
OFF
OFF
OFF