background image

3.  Remove one or more of the jumper cap as 

shown

 

in the diagram below.

Caution :

1. Address code of Control Center must be the 

same

 

as address code of Receiver. For

 

any 

jumper cap removal of

 

address code # in Control 

Center, same

 

address code # of Receiver must 

be put to the UP

 

position.

2. Disconnect AC power and remove batteries 

before

 

adjusting address code.

Remove one or more of
the jumper cap to adjust
RF address code.
Address code # 1 - 5,
from left to right

ARATON 2100 TX

7

DIP

1

2

3

4

5

ON

Push up one or more of the
white levers to adjust
Receiver address code.
Address code # 1 - 5, from
left to right.

Summary of Contents for 2100 TX

Page 1: ...AURATON 2100 TX Advanced Remote Control Programmable Thermostat ARATON 2100 TX 1 ...

Page 2: ...nits The Receiver serves for wiring connections and heat cool on off control The Control Center serves as user interface and temperature sensing control The two units are linked by RF The advantage is that user can put the Control Center nearby and can read control the temperature of really the living area 1 1 Outlook of Control Center 1 Conf Econ button 2 Up button 3 Set Time button 4 Reset butto...

Page 3: ...oler on icon 2 Comf icon 3 Econ icon 4 Program number 5 Manual Override Icon 6 Day Indicator 7 Clock 8 Anti freezing icon 9 Battery low icon 10 Temperature 11 Control profile bar ARATON 2100 TX 3 1 2 3 4 5 7 6 8 9 10 11 ...

Page 4: ...ated with the state of the art programmable thermostat 1 5 Control Center Can be placed at user living area to detect and control the temperature of the area where user really take activates Not limited by power control wiring locations 4 ARATON 2100 TX LED Indicators Front View Front Cover Power switch Connect to Heating Cooling Device Connect to Live Connect to Neutral ...

Page 5: ...efined control profiles 3 user programmable control profile A protection against freezing Temporary override set temperature User selectable temperature span User selectable heater cooler operation mode Battery level detection 2 AA size alkaline batteries not included Slim housing design EL backlight 1 6 Receiver Linked with Control Center via RF Power control rating up to 230VAC 16A resistive Pow...

Page 6: ...ing tape Screwdriver Drill and 3 16 drill bit if not installed on a junction box 2 2 RF Address Code Setting If there is another user nearby e g in the next house installs the same AURATON 2100 TX unit your receiver may be fault triggered by his her transmitter You may select a different RF address code to prevent this Receiver can only response to RF coding with the same address code setting as i...

Page 7: ...ode in Control Center same address code of Receiver must be put to the UP position 2 Disconnect AC power and remove batteries before adjusting address code Remove one or more of the jumper cap to adjust RF address code Address code 1 5 from left to right ARATON 2100 TX 7 DIP 1 2 3 4 5 ON Push up one or more of the white levers to adjust Receiver address code Address code 1 5 from left to right ...

Page 8: ... a small distance from the wall Do not disconnect any wire yet simply locate the wires WARNING After removing the wall plate if you find that it is mounted on a junction box e g a box similar to one behind a light switch or electric outlet high voltage circuit may be present and there is a danger of electric shock Please consult a qualified electrician 2 4 Wire Labeling 1 Disconnect and identify e...

Page 9: ... flush with the wall 4 Connect the wires 5 Push on the wires in the wall 6 Fasten securely the Receiver to the wall with the two screws 7 Cover up the unit with the front cover and installation is completed 2 6 Mounting the Receiver onto the optional wall box 1 Remove the front cover of the Receiver 2 Mark the holes position for the wall box 3 Drill two holes and insert the plastic anchors careful...

Page 10: ...ng system Wire connection is as follows III SETTING OF CONTROL CENTER 3 1 Heater Cooler Selection Before making any selection in the control center its back housing must be removed as follows 10 ARATON 2100 TX Neutral Output Input Remove the front housing Push and hold internal lock by a screw driver ...

Page 11: ...e Span Selection Span is the temperature difference between the turn on temperature and turn off temperature For example in heating system if you set temperature to 20 C and span to 1 C the heater will operate when the room temperature drops to 19 5 C and turns off when the temperature rises to 20 5 C Set the DIP switch position 1 2 according to your selection of temperature span as the following ...

Page 12: ... main switch of the system press the reset button once The thermostat is ready for use 3 4 Setting Clock 1 Press the button to clear all digits except the day indicator and the time display The Day indicator is flashing 2 While Day indicator is flashing press or button to adjust 3 Press the button again hour digits are flashing instead of day indicator Press or button to adjust Press and hold the ...

Page 13: ...able mode 3 Press the or button to increase decrease the set temperature by 0 5 C 4 Press the button again to save the set temperature 5 The unit will back to normal operation mode if no button is pressed for 10 seconds 6 The default setting of comfortable mode is 21 C for heater mode and 23 C for cooler mode And the economic mode is 18 C for heater mode and 26 C for cooler mode ARATON 2100 TX 13 ...

Page 14: ...re defined 1 Press the SET PROGRAM button again the day indicator stop flashing and the program number starts flash 2 Press the or button to select the program profile P1 P6 are predefined program their profile are shown as follows 00 06 12 18 24 00 06 12 18 24 00 06 12 18 24 00 06 12 18 24 Program number Program profile 00 06 12 18 24 00 06 12 18 24 Program 1 Factory preset Whole day comfort Prog...

Page 15: ...e setting hour digit by one Example button is pressed Hour Digit Clock is 2 and the 02 hour bar is flashing icon is on and the operation mode for hour 01 is set to economic mode 5 Press the button will terminate the setting procedure and back to normal operation mode Example button is pressed Terminate the setting procedure and the new control profile is 6 The setting procedure will terminate auto...

Page 16: ...the receiver 5 Repeat steps 1 to 3 6 The receiving range between Control Center and Receiver is 100M in open area When placed indoor this distance may be shorter because of blocking by concrete wall etc but is enough for most household application 7 Press RESET button after receiving range testing V TEMPORARY OVERRIDE 5 1 Override the Operation Mode At the normal operation mode press the CONF ECON...

Page 17: ...and back to normal mode with the new setting 3 The unit will back to normal operation mode automatically when no button is pressed for 10 seconds VI ANIT FREEZING MODE 1 Pressing the and buttons simultaneously will activate the anti freezing mode for heater mode only The ANTI FREEZING icon and the icon will be turned on while both the and icon will be turned off 2 Pressing any button will terminat...

Page 18: ... housing and stand 5 Press the reset button once and then turn on the power switch of the Receiver IX POWER SWITCH There is a power switch on the Receiver When there is no demand to turn on the heating cooling device e g when you go out for long vacation it is recommended to turn the power switch at Off position X LED INDICATOR There are Two LED on Power Control Unit as status indicator 1 Red LED ...

Page 19: ...Control Center 2 AA LR6 batteries Receiver 230VAC 50Hz Switching cap 16A for resistive load 8A for inductive load Clock accuracy 60 seconds month Temp measurement 0 C to 40 C in 0 5 C resolution ARATON 2100 TX 19 Temp accuracy 1 C at 20 C Temperature Control 7 C to 30 C in step of 0 5 C Span 1 2 3 or 4 C Air conditioner cycle time 3 minutes Operation temperature 0 C to 40 C Storage temperature 10 ...

Reviews: