Air conditioning mode
- set it when AURATON Libra R is to
cooperate with air conditioning devices.
Turn the knob to the left or right to set the desired mode. Confirm the selection by
pressing the button
(
. AURATON Libra R will proceed to change the next
parameter.
Hysteresis change
The hysteresis is to prevent too
frequent switching on of the actuator
due to small temperature fluctuations.
For example, for the
HI 2
hysteresis,
when the temperature is set to 20 ° C,
the boiler will be switched on at 19.8 °
C, and switched off at 20.2 ° C. For
the
HI 4
hysteresis, when the
temperature is set to 20 ° C, the
boiler will be switched on at 19.6 ° C,
and switched off at 20.4 ° C.
The hysteresis change mode is signaled by the flashing text
HI
. Turn the knob to the
left or right to set the required hysteresis.
HI 2
- ± 0.2 ° C (factory set),
Introduction to programming
programming
Manual control
Anti-freeze temperature
Description of AURATON Fornax
Pairing AURATON Libra R of a weekly, wireless
temperature controller (transmitter) with AURATON
Fornax - a wireless controller for a heating or air-
conditioning device (receiver)
RESET AURATON Libra R
MASTER RESET AURATON Libra R
Configuration settings
PWM operating mode
Special situations
Unique features of AURATON Fornax
Additional remarks
Connection diagram of AURATON Fornax
Cleaning and maintenance
Technical data
Disposal of the device
To download
Weekly, wireless temperature controller with
AURATON Fornax heating or air conditioning
controller (set)
The description of AURATON Libra R
The first launch of AURATON Libra R.