14
Pairing the wireless temperature regulator
with the RTH receiver
NOTE:
The wireless temperature regulator sold with the receiver is
already paired.
Devices sold separately require “pairing”.
3
. A properly completed pairing process is signalled by the LED on the receiver
no longer flashing green and the receiver reverting back to normal
operation.
In the event of an error during the pairing process, repeat steps 1 and 2.
Should more errors occur, deregister all devices by executing the RESET
function of the receiver (see “RESET - Deregistering all devices paired with
the receiver”) and attempt to pair the device again.
NOTE:
One receiver can have only one temperature regulator assigned.
1
. The
process of pairing
the regulator with the
receiver is initiated by pressing the left
pairing button (marked with a green triangle
- ) on the receiver and holding it for at least
2 seconds, until the LED starts flashing
green, and then releasing the button.
The AURATON RTH receiver waits for pairing
for 120 seconds. After that time, it
automatically returns back to normal
operation.
2
.
transmission symbol ( ) appears on the display. Release the button - the
regulator transmits the pairing signal for 5 seconds.
On the regulator, press the
button and hold it for 5 seconds until the
{prog}
{}
LED
15
Deregistering the regulator from the receiver
1
.
Deregistering
the temperature controller from
the receiver is initiated by pressing the right
deregistering button (marked with a red
triangle - ) on the receiver and holding it for at
least 2 seconds, until the LED starts flashing
red, and then releasing the button.
The AURATON RTH receiver waits for
deregistering for 120 seconds. After that time,
it automatically returns back to normal
operation.
LED
3
. A properly completed deregistering process is signalled by the LED on the
receiver no longer flashing red and the receiver reverting back to normal
operation.
In the event of an error during the deregistering process, repeat steps
1 and 2. Should more errors occur, deregister all paired devices (see “RESET -
Deregistering all devices paired with the receiver”) and attempt to pair the
device again.
2
.
transmission symbol ( ) appears on the display. Release the button - the
regulator transmits the pairing signal for 5 seconds.
On the regulator, press the
button and hold it for 5 seconds until the
[prog]
Summary of Contents for S03 RTH