Safety 

– CAUTION 

  This UPS utilizes voltages that may be hazardous. Do not attempt to 

disassemble  the  unit.  The  unit  contains  no  user  serviceable  parts. 
Only factory service personnel may perform repairs.   

  Internal  battery  voltage  is  24Vdc.  Sealed,  lead-acid,  6  cells  battery 

two pcs. 

  Connection  to  any  other  type  of  receptacle  other  than  a  two-pole, 

three-wire grounded receptacle may result in shock hazard as well as 
violate local electrical codes. 

  In the event of an emergency, press the OFF button and disconnect 

the  power  cord  from  the  AC  power  supply  to  properly  disable  the 
UPS. 

  Do  not  allow  liquids  or  any  foreign  object  to  enter  the  UPS.  Do  not 

place beverages or any other liquid-containing vessels on or near the 
unit.   

  This  unit  intended  for  installation  in  a  controlled  environment 

(temperature controlled, indoor area free of conductive contaminants). 
Avoid  installing  the  UPS  in  locations  where  there  is  standing  or 
running water, or excessive humidity. 

  Do not plug the UPS input into its own output. 

  Do not attach a power strip or surge suppressor to the UPS. 

  Do  not  attach  non-computer-related  items,  such  as  medical 

equipment,  life-support  equipment,  microwave  ovens,  or  vacuum 
cleaners to UPS 

 

To  reduce  the  risk  of  overheating  the  UPS,  do  not  cover  the  UPS’ 
cooling  vents  and  avoid  exposing  the  unit  to  direct  sunlight  or 
installing  the  unit  near  heat  emitting  appliances  such  as  space 
heaters or furnaces. 

  Unplug  the  UPS  prior  to  cleaning  and  do  not  use  liquid  or  spray 

detergent. 

  Do not dispose of batteries in a fire as they may explode. 

  Do  not  open  or  mutilate  the  battery  or  batteries.    Released 

electrolyte is harmful to the skin and eyes.    It may be toxic. 

  A battery can present a risk of electrical shock and high short circuit 

current.  The  following  precautions  should  be  observed  when 
working on batteries: 

1)  Remove watches, rings, or other metal objects from the hands. 
2)  Use tools with insulated handles. 
3)  Wear rubber gloves and boots. 

Summary of Contents for 1.2K

Page 1: ...User s Manual AURORA 1 2K 2 2K Uninterruptible Power System...

Page 2: ...the UPS in locations where there is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not att...

Page 3: ...rom the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or se...

Page 4: ...Overload of the UPS 1 Remove some non critical load 2 Battery voltage is too low 2 Charge battery 8 hours or more 3 Battery defect due to high temperature operation environment or improper operation...

Page 5: ...turn it to the place of purchase 2 Charging This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during shipping and the battery should be rech...

Page 6: ...the ambient temperature or humidity is high On the other hand place the UPS away from the monitor at least 20cm to avoid interference 4 Connection Plug the UPS into a 2 pole 3 wire grounded receptacl...

Page 7: ...the UPS when AC utility power is not available simply press the power switch 7 Green Power Function All Aurora UPS is equipped with Green Power Function For saving power and protecting battery the me...

Page 8: ...to 3th green Led lighting to indicate load level LED1 green 66 load level LED2 green 33 load level LED3 green 0 load level Backup Mode Green flashing The 4st green blinking Optional The 1st to 3th gre...

Reviews: