PV Temperature Sensors 

This sensor is designed to attach directly to any solar panel. When 

placed on the center back side of the panel, it accurately measures 

the temperature of the panel. 
Prior to installation of the PV temperature sensor onto the PV panel, 

the installation area of the panel back should be thoroughly cleaned. 

This cleaning will ensure a good bond between sensor and panel 

and allow for accurate panel temperature readings.  
After cleaning, peel off the protective adhesive tape on the 

temperature sensor and stick it onto the back of the panel. Firmly 

press the sensor into place. Refer to the picture on the right. The 

cable should be secured within 8 inches of the temperature-sensing 

element. 
Run the cable back to the weather station unit and connect to the PV 

temperature sensor terminals. 
If the cable length is insufficient for the installation, additional cable 

can be added to the existing cable. If this is done, an accuracy 

derating factor must be added to the overall temperature accuracy 

of this sensor. For every 100ft of cable added, an accuracy derating 

factor of -0.125°C must be taken into account. 
 
 

Cabling Requirements to Management System 

The maximum cable distance between weather station and the SunSpec-compliant management 

system is 1000 m (3000 ft). 
High-voltage areas of power plants are “electrically noisy” environments so shielded cable is advised 

for connection from the weather station to RS485. If outdoor exposure or proximity to a noise source 

is a concern, Beldon 1120A or equivalent cabling should be used.  
Cables to external sensors are supplied with the sensor. 

Summary of Contents for VSN-ENVIRO-CMML

Page 1: ...THE MANUAL AURORA ENVIRONMENTAL Model Number VSN ENVIRO ENTRY VSN ENVIRO CMML...

Page 2: ...omparison to predicted environmental data and actual inverter solar panel output The RS485 port of the Aurora Environmental Appliance is attached via low voltage wires to the monitoring or management...

Page 3: ...Pyranometer Ambient Temperature Sensor Connector Case PV Panel Temperature Sensors Second Pyranometer For Solar Panel Plane Vane for Wind Speed and Direction Mounting Mast Pyranometer Mounting Mast Co...

Page 4: ...n Ambient air temperature and irradiance measurements can be affected by obstructions local topography and surface type Each site is different and presents unique challenges By far the most important...

Page 5: ...mounts in the ground or attached to structures that support up to 50 lbs are recommended For ground tripod mounts the ground should be as level as possible For roof mounts avoid locating the station n...

Page 6: ...array pyranometer is mounted on the side of the solar array The sensor should be at the same zenith and azimuth angle as solar array to correctly measure the plane of array irradiance Anemometer Comm...

Page 7: ...g element Run the cable back to the weather station unit and connect to the PV temperature sensor terminals If the cable length is insufficient for the installation additional cable can be added to th...

Page 8: ...lip the unit over and remove the cover Find the 24VDC power connectors on the electronics board in the case Connect power to the 3 pin screw terminal inside the connection case The power supply is nom...

Page 9: ...tion and the management system to complete the physical connection The connection to the management system can be as a single RS485 device or as part of a daisy chain of RS485 devices Cable is not sup...

Page 10: ...5 Attach the second Pyranometer to your array The sensor should be attached so top of the sensor is in the same plane as the PV panels The sensor comes pre attached to a bracket for easy installation...

Page 11: ...rminal 1st Sensor PV Temp 1 Signal Black or White PV Temp 1 Signal Black or White Shield Cable Shield and Drain bare PV Temperature Terminals 2nd Sensor PV Temp 2 Signal Black or White PV Temp 2 Signa...

Page 12: ...Shield Cable Shield and Drain bare Complete the Installation 1 Properly ground the weather station by connecting the Earth GND terminal at the Weather Station to an earth ground Connecting the Earth...

Page 13: ...ires for the 24VDC power and RS485 to the Aurora Universal See the figure below Note that some Aurora Universal models may have RS485 connection points in other locations Weather Station Connection to...

Page 14: ...in Hardware Stainless Steel and Nylon Locknut Foam Gasket Vinyl and Acrylic Enclosure RoHS Compliant IP65 Rated Outdoor Enclosures UL 94 V 2 Polycarbonate Body Pyranometer Sensor RoHS Compliant Body A...

Page 15: ...Time Constant 30 sec PV Panel Temperature Sensors Range 40 to 80C 40 to 176 F Accuracy 0 3 C 0 54 F Thermal Time Constant 270 sec Cable Length 7 62m 25 ft Anemometer Operational Temperature 40 to 60 C...

Page 16: ...omer Support E mail service us power one com www power one com 2011 2012 Power One Corporation Power One is a registered trademark and Aurora Vision is a trademark of Power One Corporation All rights...