Wiring Instructions for the Aurora Environmental
Supply 24VDC Power
1.
Run wire from the 24VDC power source to the weather station.
2.
Find the back of the connection case on the weather station. Unscrew the four retaining
screws at the corners with a Philips screwdriver. See the figure below.
Weather Station Connection Case (Back View)
3.
Flip the unit over and remove the cover. Find the 24VDC power connectors on the
electronics board in the case. Connect power to the 3-pin screw terminal inside the
connection case.
The power supply is nominally rated for 24VDC but can accept a voltage in the range of
10 to 30VDC. The inputs are reverse polarity, surge, over-voltage, and over-current
protected. The power supply is not isolated.
Power Supply Terminals
Earth Gnd:
Earth or Chassis Ground
Gnd:
Negative Supply Voltage
24VDC
Positive Supply Voltage
Four Screws to
Remove Front Cover