10. Safety Messages 

Under normal operating conditions: 

1.

 

The water temperature from the outlet pipe will not exceed 100

°

C. 

2.

 

When water reaches the pressure relief valve the water temperature will not exceed 93

°

C. 

3.

 

When the water temperature reaches 100

°

C the input energy would not exceed the energy 

released. 

The knob can only adjust the temperature to a maximum of 75

°

C, when the temperature reaches 

75

°

C the power cycles automatically. The heater will also power off when the thermos-limiter 

reaches 93

°

C. If both the knob and the thermos-limiter have failed and the temperature reaches 

99

°

C, the T&P valve will drain away the water. 

For inhibition of legionella, every 7 days the following water temperature and times must be held in 
the tank. 

 

Remark: 

The red light will turn on when the supply voltage is 240V AC / 1000W. In these conditions the water 
heater will take 45 minutes to heat the water from 15

°

C to 75

°

C and the light will turn off once the 

temperature on the temperature knob is reached. 

The blue light will turn on when the supply voltage is 12V DC / 300W. In these conditions the water 
heater will take 2 hours 15 minutes to heat the water from 15

°

C to 70

°

C and then the blue light will 

turn off. 

Installation shall comply with AS/NZS 3500.4 and any relevant Australian Standards and industry 
codes. 

 

Summary of Contents for AQU-1

Page 1: ...Water Heaters Duoetto MK2 Aqueous MK2 DUO 10 AQU 10 www ausj com au sales ausj com au P O Box 777 Leichhardt NSW 2040 Last updated 20 11 17 The most up to date version of the manual is available at www ausj com au ...

Page 2: ...C on 240V and 30 C to 75 C on 12V Duoetto only It will sustain the set temperature when in operation Durable and Elegant The exterior shell is made of high quality plastics and is both elegant and durable The tank inside is made of SPCC steel enamel Environment Friendly and Efficient The polyurethane insulation provides excellent heat preservation saving electricity by maintaining the temperature ...

Page 3: ...262x267mm Mounting Mode Wall or Floor Wall or Floor 4 Safety Cautions Electrical safety requires that this unit be earthed according to the working rules of installations of electrical goods The location this water heater is installed in should be able to support four times the weight of the water system when it is full of water Approx 40kg The water heater must be filled with water before being g...

Page 4: ...ressure relief safety valve onto the cold water inlet It is recommended that you use a liquid thread sealer to ensure a non leaking fitting We recommend adding a one way valve to the cold water in to avoid water feeding back to the main water supply pipeline Notices No responsibility is taken by the manufacturer for damage caused to the unit when not using the supplied pressure relief valve If the...

Page 5: ... source this is crucial for 12V operation of the heater Important To avoid draining the engine crank battery the red small positive wire must be connected to a switch or an ignition source Applicable for the DUO 10 12V type only 6 Methods of Usage Plug in the water heater after making sure it is filled with water Turn the thermostat to the desired temperature and switch the heater on Indicator lig...

Page 6: ...al pressure is higher than the rated tank pressure the safety valve will automatically release pressure It is normal that water is blown down from the pressure relief outlet 7 Guarantee Certificates The guarantee on this water heater is 12 months within Australia from the date of sale Supply of spare parts is carried out free of charge within the warranty period Note Infringement of the instructio...

Page 7: ...9 12V Cable Length and Current Capacity Guide Current Length Twin to area sq mm 12 6VDC current carrying capacity CCC top then follows 5 volt drop to 70 sq mm ...

Page 8: ...failed and the temperature reaches 99 C the T P valve will drain away the water For inhibition of legionella every 7 days the following water temperature and times must be held in the tank Remark The red light will turn on when the supply voltage is 240V AC 1000W In these conditions the water heater will take 45 minutes to heat the water from 15 C to 75 C and the light will turn off once the tempe...

Page 9: ...e note in the event of this document and the original purchase invoice not being provided warranty will commence from the date of manufacture Owner s Details Surname Initial Address Date of Purchase Purchased from Model Serial Number Installer s Details Date of Installation Installer s Name Address Installer s Signature ...

Reviews: