Section 03
ENGINE
Subsection 07
(MAGNETO SYSTEM)
VMR2004_130_03_07A.FM
03-07-5
Installation
With Magneto Housing Cover Removed
Using the oil seal installer (P/N 529 035 759) and
the inserting jig handle (P/N 420 877 650), install
the oil seal in its location.
NOTE:
Never use oil in the press fit area of oil seal.
1. Oil seal
2. Oil seal installer (P/N 529 035 759)
3. Handle for insertion jig (P/N 420 877 650)
Reinstall other removed parts in the reverse order.
CAUTION:
Always use the oil seal protector
(P/N 529 035 935) to avoid damaging the oil seal
during magneto housing cover installation.
Without Magneto Housing Cover Removed
Using a suitable tube, with the proper diameter,
install the oil seal as per following illustration.
1. Oil seal
2. Oil seal protector
3. Tube
CAUTION:
Use the oil seal protector (P/N 529
035 935) to avoid damaging the oil seal during
installation.
STATOR
Removal
Remove:
– magneto housing cover
no. 6
– screws
nos. 8
and
9
– stator
no. 11
.
1. Stator
2. Stator screws
3. Holding strip
4. Holding strip screw
Inspection
Check stator condition. If damaged replace it.
For electrical inspection, refer to CHARGING SYS-
TEM.
Installation
For installation, reverse the removal procedure.
However, pay attention to the following.
CAUTION:
When installing the stator take care
that the cable is in place (guide for the wire).
R400motr10A
1
2
3
1
R400motr09A
3
2
4
R400motr11A
2
3
1