AUSCROWN
LPG BLOW TORCH
Rambo
RB14355
UNITS CONVERSION INDEX
PRESSURE
1 kPa = 10 mbar
= 7.5 mmHg
= 0.29 inHg
= 101.97 mmH 0
2
= 4.01 inH 0
2
= 0.145 psi
HEAT CAPACITY
1 MJ/hr = 948.45 BTU/hr
= 240.8 kcal/hr
= 277.8 W
EXAMPLE: CONVERT MJ/HR TO BTU/HR
CK107LP Heat Capacity = 12.5MJ/hr
1MJ/hr = 948.45 BTU/hr
Convert
CK107LP Heat Capacity = 12.5 x 1MJ/hr
= 12.5 x 948.45BTU/hr
= 11855.62 BTU/hr
RBFB01 RBFB02 RBFB03 RBFB04 RBFB05 RBFB06
FB2
FB1.5
Product name
Model
RBFB01 RBFB02
RBFB03
RBFB04
RBFB05
RBFB06
FB2
FB1.5
Heat Capacity
200
98
58.8
29.4
19.6
14.7
Gas Consumption
4.1kg/hr
2.0kg/hr
1.2kg/hr
0.6kg/hr
0.4kg/hr
0.3kg/hr
Jet Size
Ø1.55mm Ø1.00mm Ø0.60mm
Ø0.55mm
Ø0.35mm
Ø0.25mm
Burner Diameter
42mm
32mm
29mm
25mm
19mm
18mm
51mm
38mm
Length
108
91
87
84
70
67
113mm
103mm
Net Weight
0.21
0.12
0.11
0.09
0.08
0.07
0.23kg
0.16kg
Gas Type
Gas Pressure
Inlet Fitting
Recommended 400kPa
Internal M20x1 RH
Brass burner
Stainless steel burner
LP Gas
RB80203
RB40101
RB25063
RBBTH
Handle
Neck tubes
Flame burners
Product name
Handle
Model
RB14355 RB80203 RB40101 RB25063
RB-BTH
Length
350mm
200mm
100mm
65mm
215mm
Net Weight
0.16kg
0.12kg
0.08kg
0.07kg
0.31kg
Inlet Fitting
External M20x1RH
Outlet Fitting
External M14x1RH
Neck tube
Internal M14x1 RH
External M20x1 RH
Summary of Contents for 3012NG