OVERSPEEDING
Do not operate machine at over the maximum
rpm. Over speeding can cause serious pump
damage.
EXCESSIVE BYPASS
Do not run on excessive by-pass. Switch
machine off within five minutes of ceasing
operation as excessive by-pass can cause heat
build up in pump and subsequent damage.
Excessive bypass running voids warranty.
HIGH PRESSURE SETTING
The high pressure pump is factory set to operate
at its rated pressure. DO NOT ADJUST.
Tampering with the pressure regulator will void
warranty and can be DANGEROUS.
CHECK NOZZLE MONTHLY
If pressure drops off check nozzle for wear.
Nozzles should be replaced on a regular basis
(every month for machines in regular use, every
three months for machines used intermittently).
Using the machine with the incorrect nozzle size
or worn nozzle will void warranty and can be
DANGEROUS to the operator
.
PRESSURE CLEANER DAILY CHECK LIST
Check pump oil level
Check nozzle for wear
Check all HP components for leaks: Gun/lance, HP
hose and all fittings
Check water filter and clean if necessary
Check unloader & safety valve for leaks
THREE MONTHLY REGULAR SERVICE
All professional machines need to be thoroughly
serviced every three months. The service should
include the following;
Change pump oil
Check filter for foreign debris
Check unloader & safety valve for leaks
Check all HP components for leaks: Gun/lance, HP
hose and all fittings
Replace nozzles
SIX MONTHLY REGULAR SERVICE
To maintain the Bertolini pump warranty (three years
from date of purchase), the pump must be serviced by
an authorised service agent every six months. Contact
Aussie for your nearest agent
.
LOOK AFTER YOUR MACHINE AND IT WILL
LOOK AFTER YOU!
Australian Pump Industries Pty Ltd
7 Gladstone Road, Castle Hill NSW 2154
Ph: (02) 8865 3500 Fax: (02) 9894 4240
www.aussiepumps.com.au info@aussiepumps.com.au