Australian Pump Industries 

Page 

1               document number: QPWP151204

 

AUSTRALIAN PUMP 

 

QP WATER PUMP 

 
 
 

Inspect Unit for shipping damage immediately upon receipt.  If any damage 
exists note damage on shipping docket before signing.  Notify your Distributor 
immediately of any damage to shipment. 

 

INSTALLATION, OPERATION AND MAINTENANCE MANUAL 

 

Installation 

Location 

The pump should be located as near as possible to the liquid 
to be pumped and in no case should the pump be more than 
7m (23 feet) above the surface of the liquid supply.  The 
pump should always be as level as possible. 
 

Suction System 

Connect horizontal suction hose or pipe to suction flange.  
Pipe or hose must be self supporting without adding stress 
to pump body.  If a hose is used, it should be of the 
reinforced type to prevent collapsing under vacuum.  All 
suction system pipe or hose and connections must be free of 
air leaks, as even a very slight leak will greatly reduce 
pumping efficiency and priming ability.  The pump should be 
installed with the trash strainer on the suction line to prevent 
oversize solids from being drawn into the suction system. 
 

Discharge System 

Connect discharge hose or pipe to discharge elbow on top of 
the pump body. 
 

Operation 

Priming 

Remove the flooding cap at the top of the casing and screw 
it back tightly after filling up the casing with priming water.  
(Open the gate valve on the delivery line, if so equipped.)  In 
freezing weather use warm water if possible, to prevent 
damage to internal parts from ice.  At each subsequent start, 
check priming liquid level in pump body since the pump is 
self-priming only when the body is full of liquid. 
 

Summary of Contents for QP

Page 1: ...dy If a hose is used it should be of the reinforced type to prevent collapsing under vacuum All suction system pipe or hose and connections must be free of air leaks as even a very slight leak will greatly reduce pumping efficiency and priming ability The pump should be installed with the trash strainer on the suction line to prevent oversize solids from being drawn into the suction system Dischar...

Page 2: ...e are no suction line leaks B 5 Shutdown Operation is stopped by stopping the engine as outlined in the Engine Instruction Manual Always operate at no load for 2 or 3 minutes to allow cooling before shutdown When the pump has been operating in freezing weather or in pumping liquid containing considerable amounts of trash and or foreign matter it is advisable to remove both the drain plug and the p...

Page 3: ...et bolts evenly and tightly b Impeller a Disclose the impeller by removing the volute casing same way as above b Loosen the impeller by tapping gently with a mallet in a counter clockwise direction c Turn impeller counter clockwise and remove from shaft d Remove the mechanical seal from the impeller and set it at the back side of new impeller e Screw the new impeller on engine shaft by turning in ...

Page 4: ...ed with new rotary section spring Check to see if the mechanical seal O ring is placed correctly to the seat h Set new mechanical seal rotary section and spring with the sleeve to fit the slit of the sleeve with spring stopper i Screw the impeller as described above Troubleshooting PROBLEM CAUSE REMEDY Pump does not turn over Impeller jamming Adjust impeller spacing disassemble and clean Air leak ...

Page 5: ...L 1 USE COMMON SENSE Most accidents can be avoided by using common sense and concentrating on the job to be done 2 Do not wear loose clothing that can become entangled in operating machinery 3 Do not operate pump without guards in place 4 Do not pump hazardous material flammable caustic etc 5 Only qualified personnel should install and operate pump 6 Secure the pump after it is in its operating po...

Page 6: ...exhaust fumes when working in the area of the engine Exhaust gases are colourless odourless and deadly poison c Never operate near a building where exhaust gases can seep inside for example through an open window or a door d Never operate in a pit or sump without making provisions to suck the exhaust gases out 2 EXHAUST SYSTEM a Keep exhaust system components tight and in good working condition b ...

Page 7: ...T WATER FLOWING THROUGH IT Overheating pumps can cause severe burns and injury If overheating of pump casing occurs a Stop the pump immediately b Allow the pump to cool completely c Slowly and cautiously vent the pump C ELECTRIC MOTOR POWERED PUMPS 1 GROUND FAULT CIRCUIT INTERRUPTER Never operate a pump with a plug in type power cord without a ground fault circuit interrupter 2 WET HANDS Never han...

Page 8: ...ircuits are dead and locked out before doing any maintenance or repair work on the pump 8 MOTOR OVERLOAD Do not exceed the manufacturer s recommendation for maximum lift or discharge head as this could cause the motor to overheat Use appropriate circuit breaker for fuse 9 EXPLOSIVE ATMOSPHERE Unless the pump has been designed for it never use it in any kind of possible explosive atmosphere CAUTION...

Reviews: