17
Manually Lighting the Grill
Match
1.
Open the Hood
.
IMPORTANT:
Make sure Control Knob is turned “Off.”
2. While holding a lit match near the burner, push Burner Control Knob in and turn 90 degrees counterclockwise to
the High position. (Fig. 4)
If Burner goes out during operation, turn Control Knob to the “Off” position. Open Hood and wait five minutes before
attempting to relight the grill to allow any accumulated gas to dissipate.
Fig. 4
6TV1S
Match
Fig. 4
6TV1U
Check the Flame
To reduce the risk of death or serious injury from an explosion or a fire:
• Regularly inspect and clean Burner/Venturi Tube for insects or insect nests, especially after periods of storage. Spiders
or small insects can build nests, webs, and lay eggs in the grill’s Venturi Tube, obstructing the flow of gas to the Burner.
(Fig. 6) The backed-up gas can ignite and cause a fire. This is known as a “flashback.”
• Be sure Burner is re-installed properly before using grill.
WARNING
!
Yellow Tip
Primarily Blue Flame
1/4” tall flame minimum
Fig. 5
Burner
Venturi Tube
Valve
Control
Knob
Spider webs or nest
inside Venturi Tube
Fig. 6
The Burner has been preset by the manufacturer for optimal flame performance. A blue flame, possibly with a small yel-
low tip, is the result of the optimal air and gas mixture. (Fig. 5)
Check the flame before each cooking session and throughout the grilling season. Check the flame, especially after long
periods of storing the grill. Note that the minimum flame height should be 1/4”. If the flame is significantly yellow in
color, the appropriate amount of LP gas in the air/LP gas mixture is not correct. This could be due to a blocked Burner
from grease drippings or from insects building a nest inside the Burner or Burner opening. Should you notice that your
Burner is getting hard to light or the flame is not as hot as it once was, refer to the
“How to Clean your Burner”
sec-