13
How to perform a leak test:
Supplies Needed for a Leak Test: Clean paint brush, water
and dish washing liquid.
1) Use an LP Cylinder equipped with an OPD (Overfill
Prevention Device) and have it filled at an authorized LP
gas dealer by a qualified attendant.
2) Make sure all of the grill control panel knobs are turned to
the “off” position and verify that the LP gas cylinder valve
is closed by turning the knob on the LP gas cylinder clock
wise until it stops.
3) Mix one part of water with one part of dish washing liquid.
4) Remove Fabric Panel from the front legs if necessary.
5) Remove the Control knobs and the three screws located
under the bottom of the control panel. Lift the control panel
up and out of the way.
(FIG. 11A)
8) If “growing” bubbles appear on any of the connection
points, you have detected a gas leak. Immediately close
the LP cylinder valve by turning handle clockwise.
A) If leak appears at either end of hose and regulator
assembly, retighten the connection at the leak, but do
not over tighten. (Note: Only hand tighten at coupling
nut) Repeat Leak Test.
B) If the leak is coming from the Gas Cylinder, from the
valves at the control knobs, or if the leak cannot be
stopped, do not use the grill. Call Customer Service at
1-800-251-7558.
9) Upon completion of leak test, turn the handle on the LP
gas cylinder clockwise until it stops. Disconnect LP gas
cylinder by turning coupling nut on regulator in a counter
clockwise direction until regulator is released from
threaded LP cylinder gas nozzle.
10) Place the protective cap over LP cylinder gas nozzle.
After completing Leak Test, you are
ready to begin using your grill!
FIG. 14B
Regulator Seal
Regulator Coupling
Nut Connection
Gas Manifold Fittings
Hose Fittings
FIG. 11A
Control Panel
Open
6) Open the knob on the LP gas cylinder counter clockwise.
(FIG. 14B)
7) Check for leaks by brushing the soap solution on all gas
valves, hose connections and fittings.
(Shown by arrows
in FIG. 11A & 11B)
Make sure you generously brush the
locations with the soap solution, completely surrounding
the connections and fittings.
LIGHTING THE GRILL USING THE INTEGRA-
SPARK IGNITION SYSTEM
To reduce the risk of serious bodily injury or death:
· Open Hood before lighting the grill to prevent an
explosion from gas build-up.
· During failed lighting attempts, or if the burners go out
during operation, turn control knobs “Off” to dissipate
any accumulation of gas. Wait five minutes before
repeating lighting procedure.
· Light each burner from the left before lighting the
next burner to prevent gas from accumulating.
1. Open the Hood.
2. Important: Make sure all control knobs are
turned “Off”.
3. Turn the LP Gas Cylinder valve open counter clockwise
until it stops.
(FIG. 12A)
4. From the off position, push in and turn the left control knob
(FIG. 13)
counter-clockwise until you feel resistance.
(FIG. 12B)
Pause 4 seconds then continue turning the
control knob until a click is heard and the burner is lit.
(FIG. 12C)
Listen for the spark ignition and look to make
sure the burner is lit. If no spark, see the
Troubleshooting Section.
5. Light the remaining burners by turning the control knob
counter-clockwise. Your grill has a crossover ignition
system which allows the burners to light successively off
one another.
Confirm each burner is lit before
attempting to light another.
Summary of Contents for Bonza 3 Elite