background image

Aussie Eco-Clean Commercial Wet/Dry Vacuum Cleaners 

June 2011 

WHISPER 3000 (VC15), CLEAN AIR VC19, CLEAN AIR 

Y100W/D (Y13F1), CLEAN AIR VC40, DORSAL BACK PACK 

Congratulations on choosing an environmentally friendly Aussie Eco-Clean Product. 

IMPORTANT 

Before starting to use the machine, please note the following points and read these safety 
instructions. 

 

If you should discover any damage when unpacking the machine, please inform your Aussie 
Eco-Clean Distributor. 

 

Certain parts may be packed in the tank to protect them from damage.  These should be 
removed before the cleaner is put into use. 

 

The supply voltage must be 240V. 

1.

 

SAFETY INSTRUCTIONS 

1.1

 

Recommended Usage 

This machine is designed for professional cleaning according to these instructions, in 
particular for the removal of types of dust which may be dangerous to health (not asbestos 
material). 

1.2

 

General Safety Instructions 

This machine is designed and constructed using state of the art protective devices.  
Danger can occur in spite of this, particularly in the case of careless operation or non-
compliance with these safety instructions. 

Danger – Electrical voltage/electric current 

Contact with electrical current carries the risk of electric shock with can result in serious injury or 

even death.  Never touch damaged cables.  Always switch off and disconnect the power supply 

before carrying out any work on the machine.  Replace faulty cables immediately. 

1.3

 

Improper Usage 

Any usage of the machine for a purpose not covered under the “Recommended Usage” or 
previously agreed in writing is not permissible.  The use of the machine in an 
unserviceable condition or not in compliance with the following is prohibited: 

 

Protective devices must not be removed or bypassed. 

 

Any conversion or modification of the machine is not permitted. 

 

Defective supply cables are only to be replaced by original cables. 

 

Coupling elements between mains supply and/or extension leads must be at least 
splash-proof. 

 

The machine is to be fitted with a 10amp rated plug. 

 

Fabric filter must be in place in tank for dry vacuuming. 

1.4

 

Operator Responsibility 

It is the responsibility of the operator to ensure that: 

 

The machine is used only by personnel who have been instructed in its handling and 
who are authorised to use it. 

 

The recognised occupational safety regulations are observed. 

 

Any further national or internal company regulations are observed. 

 

All users are acquainted with the safety regulations and trained in the use of the 
specific machine. 

 

Responsibility for the operation, maintenance and repair of the machine is clearly 
assigned and observed. 

 

Faults and damage are immediately notified to the Authorised Service Agent of Aussie 
Eco-Clean. 

 

The operator is advised to wear proper soled footwear when using the unit. 

Summary of Contents for Eco-Clean

Page 1: ...um Cleaners Dry only vacs Whisper 3000 VC15 Dorsal Back Pack Wet dry vacs Clean Air VC19 Clean Air Y100W D Y13F1 Clean Air VC40 ATTENTION Operators must read this manual and understand it completely before using the machine WARNING NOT FOR USE WITH ASBESTOS MATERIAL ...

Page 2: ... cables Always switch off and disconnect the power supply before carrying out any work on the machine Replace faulty cables immediately 1 3 Improper Usage Any usage of the machine for a purpose not covered under the Recommended Usage or previously agreed in writing is not permissible The use of the machine in an unserviceable condition or not in compliance with the following is prohibited Protecti...

Page 3: ...ine for wet use only ensure that the fabric filter is NOT installed in the recovery tank Never allow the liquid to exceed maximum level in recovery tank i e when the float inside the machine rises to the vacuum cleaner head causing suction to be cut off immediately empty the recovery tank For dry use the fabric filter bag must be fitted to protect motor 2 OPERATION 2 1 Assembling Your Machine Open...

Page 4: ...tion turbine No electrical power Check fuse cable plug and socket Suction slowly decreases Filter nozzle suction hose or extension tube blocked Check and clean Suction suddenly decreases The filter is clogged with dust or tank is full Switch off the cleaner clean filter empty tank Dust escapes when cleaning Filter incorrectly fitted or defective Check filter sealing Replace filter Theelectricalcom...