Aussie Mobi-blaster … Operator’s Instruction Manual
6
Aussie Pumps
Sept 2016
UNLOADER SETTING
The high pressure unloader on the machine is factory
set to operate the pump at it’s rated pressure.
DO NOT ADJUST.
Tampering with the unloader will
void warranty and can be dangerous.
WARNING .... DO NOT RUN EXCESSIVE BY-PASS
SWITCH MACHINE OFF WITHIN TWO MINUTES OF CEASING
OPERATION AS EXCESSIVE BY-PASS CAN CAUSE HEAT BUILD UP IN
PUMP AND SUBSEQUENT DAMAGE
.
EXCESSIVE BY PASS RUNNING VOIDS WARRANTY!!
E. Pressure washing
WEAR PROPER FACE PROTECTION WHEN OPERATING
PRESSURE WASHER!
Machine is now ready for operation.
1.
For high pressure jetting rotate side grip on dual
lance backwards until it stops. Fine control of
pressure/flow can be made with small
adjustments to the rotation of the grip. There is
no pressure adjustment available on single
lance options.
2.
When low pressure and high flow is required,
including detergent application, unwind grip
two complete turns. Adjust the detergent
control on the pump as required.
NOTE
: Check the system for water leaks, fuel leaks, oil
leaks, hose kinks, etc. Correct any problems before
proceeding.
F. Applying detergent
(not available on Predator Plus)
1.
Prepare pressure washer detergent solution as
required by manufacturer.
2.
Place detergent siphon tub/filter into solution.
3.
Adjust double lance to low pressure setting.
4.
Apply cleaning solution to a dry surface, starting
at lower portion of areas to be washed and
work upward, using long overlapping strokes.
5.
Allow time to detergent to activate and then
rinse off. DO NOT allow detergent to dry on.
IMPORTANT
; You must flush the injection system after
each. Place the siphon hose into a bucket of clean
water, then run pressure washer in low pressure for 2
minutes.
G1. Stopping the machine
1.
If using the detergent injector, flush out the
chemical by running clean water through the
system.
2.
Allow machine to run for 1 minute without load
to cool before stopping.
3.
Turn engine ON/OFF switch to OFF
4.
If your machine has a recoil start, pull recoil
start until compression resistance is felt. Store
the machine in this position to help prevent
valve warpage or sticking.
5.
Close fuel valve.
WARNING:
CHECK NOZZLES AND REPLACE IF WORN
If pressure drops off, check nozzle for wear. Nozzles
should be replaced on a regular basis (every month
for machines in regular use, every 3 months for
machines used intermittently. Using the machine
with the incorrect nozzle size or worn nozzle will void
warranty and can be dangerous to the operator.
HIGH PRESSURE SPRAY CAN PENETRATE THE
SKIN & CAUSE SERIOUS INJURY!
Never point the spray gun at yourself, other people
or animals.
Should the spray penetrate the skin
SEEK MEDICAL
ATTENTION IMMEDIATELY!