PREVENTATIVE MAINTENANCE
Keep filter in supply hose connection clean, rinse
regularly.
Use correct size nozzles for machine and replace
when worn, check serial tag for correct size.
Drain water from pressure hoses, gun/lance
assembly and accessories after use.
Protect pump from freezing. Failure to remove
water from the pump in freezing temperatures will
result in damaged pump manifold.
Use ONLY injector of the size and type designed
for this model.
DO NOT
tamper with unloader valve adjustment
or alter engine speed.
DO NOT
siphon chemicals through the pump, it is
designed for water only.
Incoming water supply must not exceed 60°C,
otherwise pumps seal damage could result
Follow engine manufactures guidelines for engine
maintenance. (see engine manual)