July 2012
Raptor Electric Operator’s Manual
3
Australian Pump Industries
SAFETY FIRST
WARNING:
To comply with Australian and New Zealand standards, operator’s of 5000psi machines and
larger need to complete operational and safety training courses and be duly certified in order to comply with
Occupational Health & Safety requirements.
ATTENTION OPERATOR
Please read the Operating and Safety Instructions in this manual thoroughly before using your Aussie
Raptor water blaster. Please note that safety procedures must be followed carefully. Non-compliance can
result in severe injury or even death.
SAFETY CLOTHING
Wearing protective clothing is essential for the use of B-class machines (5000psi and above). Eye
protection, gloves, body protection, steel capped boots and ear protection equipment are essential. For
details see page 7.
WATER BLASTING OPERATION
While using the Aussie Predator, take special care to ensure the gun and nozzle are never pointed at any
person or animals. Severe injury or death may result. For details and other warnings see page 5.
BACTERIA WARNING
In the event that some person or persons may be sprayed by high pressure water, it is important medical
personnel be advised as unusual infections with microaerophilic organisms can occur. For details see
Emergency Medical Information
page 14.
SPECIFICATIONS
Performance
Raptor 12
Raptor 16
Stock code
ABRAPTOR/12EMOT
ABRAPTOR/16EMOT
Pump pressure
psi
7,300 (500 BAR)
7,300 (500 BAR)
EWP with turbo
psi
12,000
12,000
Flow
lpm
12
16
Motor Phase
Three phase
Three phase
Power
kW
4 pole, 12.5
4 pole, 15
Pump speed
rpm
1450
1450
Pump type
Penta
Penta
Pump Model
GHC12/50S
GHC16/50S
Nozzle size
020
025
Accessories - Hose
10M 1/4” 1,000 BAR
10M 1/4” 1,000 BAR
Gun
RL84
RL84
Lance
RL800
RL800
Nozzle type
Laser cut
Laser cut
Weight
kg
120
120
Boxed dimensions
LxWxH (mm)
1000 x 720 x 820
1000 x 720 x 820