background image

PAGE 6

AMB SERIES AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL

CONTROLS, CONNECTORS & INDICATORS

REAR PANEL

8

  Balanced Input

A female 3-pin combined XLR connector is provided on each input: 

Pin 1 = Signal Ground; 

Pin 2 = Hot (non-inverting or in phase); 

Pin 3 = Cold (inverting or reverse phase).

9

  Signal Strapping

A male 3-pin XLR type connector is provided and wired in parallel with the 
female input XLR for strapping / looping signal between amplifiers.

10    

  Binding Post Outputs

Touch proof binding posts (banana jacks) are provided for speaker output 
termination with banana plugs or bare wire. The red post is used as positive and 
the black post is used as negative. For bridge connection, use only the red posts.

11

  

  

 Speaker Output Connector

A 4 pole Neutrik SpeakON connector is provided as an additional speaker 
output. This standard of loudspeaker-to-amplifier connection allows access to 
both channels of the amplifier via the one connector for bi-amp applications. 
Channel 1 is considered the dominant channel and has both channels wired to 
the speaker connector. See the installation section of this manual for detailed 
information on speaker connector wiring.

12

  Mains Connection

Your amplifier is fitted with an internationally recognised IEC mains inlet 
connector.

Please ensure that the connecting mains lead for use with the IEC connector  
is of an approved type and is of sufficient current carrying ability.

 

NOTE:

 Your unit must always be earthed!

13

  Circuit Breaker

The amplifier is fitted with a resettable circuit breaker.

If the circuit breaker trips, allow 3 mins for the contacts to reset thermally 
before pushing the reset button to reset it mechanically.

14  

  Stereo/Bridge/Parallel Mono Switch

When set to STEREO, your amplifier operates as two independent channels.

When set to PARALLEL, your amplifier will only accept signal applied to  
Channel 1’s input XLR. Channel 2’s output signal will come from Channel  
1’s input but both channels will have independent attenuator control.

When set to BRIDGE mode of operation your amplifier will only accept  
signal applied to channel 1’s input XLRs and the level of both channels  
will be controlled by the Channel A attenuator. The output from Channel 2  
will automatically be of the opposite polarity (reversed phase) and speaker 
termination should be sourced from the red binding-post outputs.  
Alternatively, the speaker could be connected to poles 1+ & 2+ of the  
4 pole speaker connector (see Installation – Output Wiring on page 7). 

12

13

10

11

14

9

8

Summary of Contents for AMB1200

Page 1: ...INSTALLATION AND OPERATION MANUAL AMB SERIES AUDIO POWER AMPLIFIERS AMB600 AMB1200 AMB1600 ...

Page 2: ...ker wiring during normal operation 1 LISEZ ces instructions 2 Tenez ces instructions 3 Notez tous les avertissements 4 Suivez toutes les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez près aucunes sourc...

Page 3: ...alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance For European Union countries This symbol on the product or its packaging indicates that this product must not be disposed of with other waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point...

Page 4: ...nectors Stereo bridged Mono parallel operation Binding post and 4 pole speaker output connection Output clip indication per channel Multi role output fault indication High quality close tolerance components throughout Individual Signal LED Bar graph for status indication per channel PROTECTION FEATURES Suppression of inrush current at mains turn on Radio frequency interference suppression Short ci...

Page 5: ...mplifier is 4 Ohms per channel 8 Ohms bridged If an overload occurs the amplifier will run into a current limit mode restricting the excess current beyond set limits 4 Attenuator Level control for your amplifier is provided by a potentiometer on the front panel and indicates gain There are two controls on all AMB models Each control is labelled for the channel which it operates 5 Status Indicator ...

Page 6: ...connector wiring 12 Mains Connection Your amplifier is fitted with an internationally recognised IEC mains inlet connector Please ensure that the connecting mains lead for use with the IEC connector is of an approved type and is of sufficient current carrying ability NOTE Your unit must always be earthed 13 Circuit Breaker The amplifier is fitted with a resettable circuit breaker If the circuit br...

Page 7: ... 3 is connected to pin 1 input ground either by linking the pins in the input connector or by the source equipment s output wiring When wiring for an unbalanced source Pin 1 GROUND SHIELD Pin 2 HOT in phase with the amplifier s output Pin 3 GROUND SHIELD joins to pin 1 NOTE In line XLR connectors often have a termination lug that connects directly to the chassis of the connector IMPORTANT Do not l...

Page 8: ...oblem It is generally more difficult to eliminate this kind of interference but again moving the source away or providing a magnetic shield i e a steel shield should help Earth loops can arise from the interfacing of the various pieces of equipment and their connections to various safety earths This is by far the most common cause of hum and it occurs when source equipment and the amplifier are pl...

Page 9: ...rough an initialising period before it will accept signal The Inrush Current Suppression ICS circuit is in operation for the first 0 5 seconds This limits the mains current to prevent nuisance tripping of circuit breakers During this period you will hear a couple of relays click indicating mains is now directly applied to the amplifier and the signal path is connected While the ICS circuit operate...

Page 10: ...fan blades and reduce their cooling efficiency The time taken for this to happen will depend on the environment and the amount of use The fan blades are accessible once the lids are removed and can be easily cleaned You need only hold the fan rotor still and wipe the dust off the blades Many users stall the fan and use compressed air to blow the dust off the fan blades It is important to note that...

Page 11: ...1kHz 8Ω Input Connectors 2 Female XLR 2 Male XLR 2 Female XLR 2 Male XLR 4 Female XLR 2 Male XLR Input Impedance 20kΩ 20kΩ 20kΩ Balanced line to line Output Impedance 40mΩ 40mΩ 40mΩ Input Sensitivity 1 23Vrms 4 0dBu 1 23Vrms 4 0dBu 1 23Vrms 4 0dBu 0 2V Level control at maximum Input CMRR 55dB 55dB 55dB 20Hz 20kHz Output Connectors 4 x Binding Posts 2 x Neutrik speakON 4 x Binding Posts 2 x Neutrik...

Page 12: ...Load Power 1W 3 412BTU Hr 1 8th Power 1266 2115 2634 Excludes Load Power 1W 3 412BTU Hr 1 3 Power 1706 2661 3469 Excludes Load Power 1W 3 412BTU Hr Full Power 1952 3153 3685 Excludes Load Power 1W 3 412BTU Hr Dimensions W x D x H 88mm x 483mm x 366mm 3 5 x 19 x 14 41 88mm x 483mm x 366mm 3 5 x 19 x 14 41 88mm x 483mm x 366mm 3 5 x 19 x 14 41 Not including rack ears Shipping Dimensions W x D x H 18...

Reviews: