Mounting

Your amplifier is designed for standard 19” rack mounting and occupies 2 EIA 
rackunits (3.5”). 

The mounting centres are: 
Vertical: 3.0” (76.2mm)   Horizontal: 18.2” (461.2mm) to 18.7” (473.8mm)

The slots in the mounting flange will accept bolt diameters up to 1/4” 
(6.35mm). We recommend that you provide additional support for the amplifier, 
especially if road use is planned, as the weight could bend some rack frames. 
This support can be provided by secure shelving on support rails. 

When rack mounting, it is advisable to allow 1 rack space above and below the 
amplifier. When multiple amplifiers are mounted in a rack, exhaust fans should 
be used on the rack. Airflow for cooling the AMC+120P is by convection from 
bottom to top. Airflow for cooling the AMC+250P is by fan from front to side.

Disconnect all cables and power sources from the amplifier before mounting in 
the rack.

Mount the amplifier so that hazardous conditions are not achieved due to 
uneven mechanical loading.

Position the amplifier in the mounting rack so that the four slots in the 
mounting ears are aligned with the rack mounting holes. Fasten the amplifier 
using four screws to suit the nuts/threads in the rack.

Montage

Cet ampli convient pour un montage en rack de 19” et a 2 unités de 3.5”.

Les centres de montage sont: 
Vertical: 3.0” soit 76.2 mm   Horizontal: de 18.2” (soit 461.2mm) à 18.7”  
(soit 473.8 mm). 

Vous pouvez mettre des vis de 6.5 mm maximum dans ls fentes de la bride de 
montage. Nous vous recommandons un support supplémentaire car le poids 
peut parfois faire plier le chassis en cas d’usage intensif. 

Lorsqu’un amplificateur est installé dans un rack, il est conseillé de laisser 
1 espace libre au-dessus et en dessous de l’amplificateur. Si plusieurs 
amplificateurs sont installés dans un rack, il est recommandé d’installer les 
ventilateurs .

Le débit d’air pour le refroidissement de l’AMC 120 P se fait par convection de 
bas en haut. Le débit d’air pour le refroidissement de l’AMC 250 P est effectué 
par le ventilateur de l’avant vers l’arrière.
Débranchez les câbles et les sources d’alimentation de l’amplificateur avant de 
le monter dans le rack.

Veuillez installé l’amplificateur à l’intérieur du rack de telle sorte que l’appareil 
soit stable afin d’éviter une chute.

Positioné l’amplificateur dans le rack de sorte que les quatre fentes soit 
alignées avec les trous de montage du rack. Visser l’amplificateur au rack en 
utilisant quatre vis.

PAGE 6

AMC

+

 SERIES INSTALLATION AND OPERATION MANUAL

INSTALLATION

Summary of Contents for AMC+120P

Page 1: ...INSTALLATION AND OPERATION MANUAL POWER AMPLIFIERS AMC 120P AMC 250P AMC SERIES ...

Page 2: ... les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez près aucunes sources de chaleur comme radiateurs registres de chaleur fours ou les autres équipements y compris amplificateurs qui produisent la chale...

Page 3: ...TO PREVENT ELECTRICAL SHOCK MATCH WIDE BLADE PLUG TO WIDE SLOT FULLY INSERT CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbo...

Page 4: ... or off the mains The up position is on 3 Vents Air intake for fan cooling on AMC 250P only To indicate hazards arising from dangerous voltages Pour indiquer les risques résultant de tensions dangereuses Hot surface Don t touch here PAGE 4 AMC SERIES INSTALLATION AND OPERATION MANUAL FRONT PANELS ...

Page 5: ...t continued Minimum Impedance AMC 120P AMC 250P Distributed Line Output 70V 41ohm 20ohm 100V 83ohm 40ohm Low Impedance Output both versions 4ohm 4ohm NOTE Only connect one output either Distributed Line or Low Impedance per channel Do not connect LowZ and 70 100V at the same time The output strip comes fitted with a touch proof cover held in place by two M3 machine screws with flat and spring wash...

Page 6: ...o suit the nuts threads in the rack Montage Cet ampli convient pour un montage en rack de 19 et a 2 unités de 3 5 Les centres de montage sont Vertical 3 0 soit 76 2 mm Horizontal de 18 2 soit 461 2mm à 18 7 soit 473 8 mm Vous pouvez mettre des vis de 6 5 mm maximum dans ls fentes de la bride de montage Nous vous recommandons un support supplémentaire car le poids peut parfois faire plier le chassi...

Page 7: ...shielded pair cable is recommended NOTE When wiring the LINE output as unbalanced Pin2 should be wired as hot and Pin1 should be wired as ground shield Do not wire Pin3 REC Output The REC output wiring should be kept as short as possible Input Connections For wiring balanced in pin 2 is hot Unbalanced wiring on the microphone inputs is not recommended Balanced input wiring shielded pair cable is r...

Page 8: ... turned up Check speaker loads for shorts Reduce input level at source Reduce volume levels on front panel Reduce Bass control level No sound but amp is on Volume controls down Amplifier has overheated AMC 60 AMC 120 AMC 250 only DC fuse s blown Check volume controls Check for obstructions above and below Make sure the amplifier is well ventilated Refer product to local Australian Monitor dealer P...

Page 9: ...PAGE 9 AMC SERIES INSTALLATION AND OPERATION MANUAL BLOCK DIAGRAM ...

Page 10: ...dio Amplifier Model AMC 120P Rated Value 115V 60Hz 460W 230V 50Hz 460W Manufacture Date Made In China CERTIFIED TO CAN CSA STD C22 2 No 60065 CONFORMS TO ANSI UL SYD 60065 230 V FUSE T2AH 250V 115 V FUSE T4AH 250V PAGE 10 AMC SERIES INSTALLATION AND OPERATION MANUAL DIMENSIONS ...

Page 11: ... 27 6lb 30 8lb SHIPPING DIMENSIONS WxHxD 525 x 175 x 385mm 525 x 185 x 470mm 20 7 x 6 9 x 15 2 20 7 x 7 3 x 18 5 MAINS CURRENT DRAW 230V FULL POWER 1 20A 2 53A 1 3 POWER 0 80A 1 61A 1 8 POWER 0 55A 1 10 IDLE 0 15A 0 15A MAINS CURRENT DRAW 115V FULL POWER 2 50A 5 28A 1 3 POWER 1 67A 3 36A 1 8 POWER 1 15A 2 30A IDLE 0 31A 0 31A THERMAL OUTPUT W FULL POWER 128W 259W 1 3 POWER 118W 231W 1 8 POWER 91W ...

Page 12: ...PAGE 12 AMC SERIES INSTALLATION AND OPERATION MANUAL NOTES ...

Page 13: ...PAGE 13 AMC SERIES INSTALLATION AND OPERATION MANUAL NOTES ...

Page 14: ...iries email international australianmonitor com au DISTRIBUTED IN AUSTRALIA AND NEW ZEALAND BY HILLS SVL www hillssvl com au NSW QLD ACT WA VIC SA NZ P 02 9647 1411 P 07 3852 1312 P 02 6260 4544 P 08 9204 0200 P 03 9890 7477 P 08 8408 8300 P 09 415 9426 E nsw hillssvl com au E qld hillssvl com au E act hillssvl com au E wa hillssvl com au E vic hillssvl com au E sa hillssvl com au E sales hillssvl...

Reviews: