Protection
Internal current limiting protects the amplifier from both overload and
overdrive conditions. Australian Monitor Installation Series amplifiers
feature a protection network that provides greater stability and
performance. Our amplifiers are recognised worldwide for their reliability
and this is due to the extensive levels of current limiting which protect
the amplifiers from both overload and overdrive conditions.
AMIS 120
AMIS 120
AMIS 120
AMIS 120
AMIS 120
ARCHITECTURAL AND ENGINEERING SPECIFICATIONS
The mixer amplifier shall have four universal input channels, each comprising of a
balanced microphone input with XLR female sockets and an auxiliary input using dual
RCA sockets. The 100V line speaker outputs should be able to be switched via a six
position selector with ”all call“. A alanced XLR output to drive additional power
amplifiers shall also be provided. This unit shall offer remote master VCA control, 24V
DC and mains power operation, and a vox triggered relay output. The amplifier master
section shall include one master gain control, two EQ controls, one with 12dB of cut
and boost at 100Hz and the other with 9dB of cut and boost and 10kHz speaker
outputs shall be transformer isolated at 100V, 70V, 4 & 8 ohms. The amplifier must be
capable of delivering 120 watts RMS into an 80 inductive ohm load, with less than
0.5% distortion measured at 1kHz and with system hum and noise less than -74dB.
The amplifier shall be an Australian Monitor Installation Series model AMIS120.
Phantom Power
Phantom Power (18V DC) is available from all mic inputs. A rear panel
phantom power on/off switch is also provided.
ABOUT
Australian Monitor
Corporate Headquarters
is located in Sydney,
Australia. The
organization has more
than 20 years experience
in the design and
manufacture of audio
amplifiers and
associated products.
They are a dynamic
corporation, priding
themselves on excellent
customer service, better
features and lower priced
products for Sound
Contractors and Audio
Visual Integrators
worldwide.