Rear Panel Features

AC Power Inlet

The 3 pin IEC power inlet is located on the bottom left of the rear panel and accepts a standard mains power lead fitted
with an IEC connector. Before plugging in a power lead, please check the rear panel of the amplifier to ensure that the
voltage label shows the correct AC operating voltage for your part of the world.

The inlet is equipped with an in-built AC fuse holder fitted with a 4 Amp slow blow fuse plus a spare fuse. Please ensure
that the mains power cord is disconnected before attempting to check or replace this fuse.
 Power consumption is 300
VA (max).

Speaker Output Terminal Strip

Located on the top left of the rear panel is the speaker output terminal strip. Reading from left to right, the connections
are:

COM

Common or “-” for low impedance speaker loads (4 or 8 ohms).

4

The “+” for 4 ohm speaker loads (use with common)

8

The “+” for 8 ohm speaker loads (use with common)

COM

Common or “-” for 70v or 100v speaker loads (maximum load of 80 ohms at 100v)

70

The “+” for 70v line speaker loads (use with common)

100

The “+” for 100v line speaker loads (use with common)

Please ensure that the correct “Common” is used. Low impedance and 70/100v loads can be used simultaneously but
please pay careful attention to the overall speaker load. When used individually, the low impedance load should be 4
ohms or higher while the 100v line load should not fall below 80 ohms. When both outputs are used simultanously,
ensure that neither output is loaded to maximum.

24 Volt Power

Located on the rear panel are the red and black connection posts for 24v power. This feature can be used as either a back-
up facility (if mains power fails) or for applications where AC power is not available. The left side red post is the +
(positive) terminal while the right side black post is the - (negative) terminal. The DC current drain is 8 Amps maximum
at full power. This socket also provides trickle charge to a DC battery supply (if connected) when the DCM120 is
operated from AC mains power. The level of trickle charge is 300 mA, maximum.

Mains Failure: The LED glows red if there is a failure in the AC mains power supply. However, this LED will only glow
if there is a DC supply voltage present. If no DC supply voltage is present then this LED will not glow.

Output Level VU Meter: A 10 segment LED VU meter is provided to give an indication of the output signal level of the
amplifier from -25 to +3 dB. During normal operation, the LED’s will oscillate with changes in the program signal. Care
should be taken to avoid more than occasional illumination of the red LED’s. If the LED’s in the red zone are lit
continually, then the output level control (or the level of the input signal to the DCM120) should be adjusted to reduce
the output level. Too much output level can cause distortion, activate the internal limiter or possibly damage the
connected speaker system.

2 30   V

2 40   V

C

C

4

1 00

8

O H M

VO LT

7 0

AC  FU S E  4 A  S /B

EN GI N EE R ED  BY AUD I O  T ELE X C O M M U N IC AT IO N S  PT Y LTD   SYDN EY AU S TR ALIA

D C   F US E

  1 0A  S /B

2 4  VD C

IN PU T

Summary of Contents for DCM120

Page 1: ...DCM120 120w Power Amplifier Operating Manual TEM P FAIL ON 24 21 18 15 12 9 6 3 0 3 HI MAIN S D C M 1 2 0 ...

Page 2: ... are connected and you rock the AC power switch to the off position the DCM120 will automatically continue to operate normally from the DC supply and the mains failure LED will also glow under these conditions Level Control The output level control is located in the centre of the front panel just to the left of the mains rocker switch re cessed screwdriver adjustable pot Turning the control clockw...

Page 3: ...tputs are used simultanously ensure that neither output is loaded to maximum 24 Volt Power Located on the rear panel are the red and black connection posts for 24v power This feature can be used as either a back up facility if mains power fails or for applications where AC power is not available The left side red post is the positive terminal while the right side black post is the negative termina...

Page 4: ...y at conservative levels and proper load conditions it is possible that the cooling fan will not switch on at any time during normal operation When operating the fan works with air flow from the front to the rear of the DCM120 Fuse Sizes Mains 240VAC 4 Amperes Slow Blow XLR Audio Input and Parallel Output The input to the DCM120 is transformer balanced 10K ohms When signal is connected to one XLR ...

Page 5: ...at producing devices 13 Do not block fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug weathersheet carpet or com pletely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be peri odically blown free of foreign matter 14 Do not remove the cover R...

Page 6: ...ey QLD 4006 Ph 07 3852 1312 Fax 07 3252 1237 E mail qld audiotelex com au Adelaide SA NT Sales P O Box 157 Hindmarsh SA 5001 31 Walsh Street Thebarton SA 5031 Ph 08 8352 4444 Fax 08 8352 4488 E mail sa audiotelex com au Perth WA Sales P O Box 404 North Perth WA 6906 299 Fitzgerald Street West Perth WA 6005 Ph 08 9228 4222 Fax 08 9228 4233 E mail wa audiotelex com au Auckland NZ Sales P O Box 512 A...

Reviews: