background image

  A

S

3606/7

 

 

Prelim

inary

 Ap

pli

c

at

ion N

o

te - 

C

onfide

n

ti

al 

 

 

www

.a

us

tr

ia

m

ic

ro

s

ys

te

m

s

.c

o

m

 (d

gm

Revi

s

ion 1v1 /

 20100309 

10 - 19 

 

 

 

Appli

c

ati

on S

c

he

mat

ic AS3

60

7 Ev

alboar

d 1v

0 –

 pag

e2 

 

Summary of Contents for 990600223

Page 1: ... constant voltage OLED supply as well as constant current white LED backlight operations with 2 current sinks are possible An internal voltage protection is limiting the output voltage in the case of external component failures AS3606 07 also contains a Li Ion battery charger with constant current and constant voltage The maximum charging current is 1A An integrated battery switch and an optional ...

Page 2: ... Demo software 6 7 AS3607 EVALBOARD 1V0 CONNECTOR AND JUMPER LOCATIONS 7 8 APPLICATION SCHEMATIC OF AS3607 EVALBOARD 1V0 9 9 AS3607 EVALBOARD 1V0 LAYOUT TOP VIEW 11 10 AS3607 EVALBOARD 1V0 LAYOUT MID LAYER 1 11 11 AS3607 EVALBOARD 1V0 LAYOUT MID LAYER 2 12 12 AS3607 EVALBOARD 1V0 LAYOUT BOTTOM VIEW 12 13 AS3606 EVALBOARD 1V1 CONNECTOR AND JUMPER LOCATIONS 13 14 APPLICATION SCHEMATIC OF AS3606 EVAL...

Page 3: ...7 are continuously updated Visit our home page http www austriamicrosystems com 4 Revision status AS3607_AN01_Evalboard Application note this document Rev 1v1 AS3607 Evalboard schematic Rev 1v0 AS3607 Evalboard layout Rev 1v0 AS3606 Evalboard schematic Rev 1v1 AS3606 Evalboard layout Rev 1v1 5 General description Remark all subsequent component numbering refers to the application schematics shown ...

Page 4: ... austriamicrosystems com dgm Revision 1v1 20100309 4 19 6 Getting Started 6 1 AS3606 07 Demo Software Installation Start the demo software Installation Shield with Install Demo Software The Install Shield will guide you through the rest of the installation ...

Page 5: ...w austriamicrosystems com dgm Revision 1v1 20100309 5 19 6 2 Connecting the Evalboard and USB Box with the PC After the successful installation of the demo software the USB Box can be connected to the PC and to the Evalboard as shown in the picture below ...

Page 6: ...rosystems com dgm Revision 1v1 20100309 6 19 6 3 Starting the AS3607 Demo software The correct installed demo software can be started from Start Programs austriamicrosystems AS3607 EvalSW USB connection is immediately indicated in the status bar of the demo software ...

Page 7: ... LED connected to VDD27 J12 VBAT Battery voltage measurement pinhead J13 CURR1 current measurement jumper of CURR1 J14 CURR2 current measurement jumper of CURR2 J15 GPIO1 if set LED D12 is connected to GPIO1 J16 GPIO2 if set LED D13 is connected to GPIO2 J17 measurement pinhead J18 I BAT current measurement jumper of battery current J20 DVDD DVDD can be supplied with one of the regulators default ...

Page 8: ...AS3606 7 Preliminary Application Note Confidential www austriamicrosystems com dgm Revision 1v1 20100309 8 19 Connector and Jumper locations of AS3607 Eval Board 1V0 ...

Page 9: ...606 7 Preliminary Application Note Confidential www austriamicrosystems com dgm Revision 1v1 20100309 9 19 8 Application Schematic of AS3607 Evalboard 1v0 Application Schematic AS3607 Evalboard 1v0 page 1 ...

Page 10: ...AS3606 7 Preliminary Application Note Confidential www austriamicrosystems com dgm Revision 1v1 20100309 10 19 Application Schematic AS3607 Evalboard 1v0 page2 ...

Page 11: ...liminary Application Note Confidential www austriamicrosystems com dgm Revision 1v1 20100309 11 19 9 AS3607 Evalboard 1v0 Layout top view Layout top view 10 AS3607 Evalboard 1v0 Layout mid layer 1 Layout mid1 view ...

Page 12: ...inary Application Note Confidential www austriamicrosystems com dgm Revision 1v1 20100309 12 19 11 AS3607 Evalboard 1v0 Layout mid layer 2 Layout mid2 view 12 AS3607 Evalboard 1v0 Layout bottom view Layout bottom view ...

Page 13: ...1 ON LED status LED connected to VDD27 J12 VBAT Battery voltage measurement pinhead J13 CURR1 current measurement jumper of CURR1 J14 CURR2 current measurement jumper of CURR2 J15 GPIO1 if set LED D12 is connected to GPIO1 J16 GPIO2 if set LED D13 is connected to GPIO2 J17 measurement pinhead J18 I BAT current measurement jumper of battery current J20 DVDD DVDD can be supplied with one of the regu...

Page 14: ...AS3606 7 Preliminary Application Note Confidential www austriamicrosystems com dgm Revision 1v1 20100309 14 19 Connector and Jumper locations of AS3606 Eval Board 1V1 ...

Page 15: ...606 7 Preliminary Application Note Confidential www austriamicrosystems com dgm Revision 1v1 20100309 15 19 14 Application Schematic of AS3606 Evalboard 1v1 Application Schematic AS3606 Evalboard 1v1 page1 ...

Page 16: ...AS3606 7 Preliminary Application Note Confidential www austriamicrosystems com dgm Revision 1v1 20100309 16 19 Application Schematic AS3606 Evalboard 1v1 page2 ...

Page 17: ...liminary Application Note Confidential www austriamicrosystems com dgm Revision 1v1 20100309 17 19 15 AS3606 Evalboard 1v1 Layout top view Layout top view 16 AS3606 Evalboard 1v1 Layout mid layer 1 Layout mid1 view ...

Page 18: ...inary Application Note Confidential www austriamicrosystems com dgm Revision 1v1 20100309 18 19 17 AS3606 Evalboard 1v1 Layout mid layer 2 Layout mid2 view 18 AS3606 Evalboard 1v1 Layout bottom view Layout bottom view ...

Page 19: ...in normal commercial applications Applications requiring extended temperature range unusual environmental requirements or high reliability applications such as military medical life support or lifesustaining equipment are specifically not recommended without additional processing by austriamicrosystems AG for each application For shipments of less than 100 parts the manufacturing flow might show d...