background image

Dexter 

12 

english 

 

5. SPECIAL FEATURES Dexter 2.0 

 

Operation with external air supply 

The German institute for constructional engineering (DIBT) has given the Dexter 2.0 the general technical  approval for 

operation with external air supply. If the combustion air is being supplied directly to the furnace by an air-tight pipe including 

closing mechanism from the outside, then the stove may be used in residential property with mechanical ventilation. 

If the stove in being used like that, a multiple stove installation on the same chimney is forbidden. 

This stove has been approved by the German DIBT. 

 

 

problem 

possible reason 

solution 

 

 

 

 

 

door glass gets sooty too fast 

 

 

bad chimney draught 

generally: door glasses must be cleaned with 

Austroflamm glass cleaner from time to time 

(depending on the frequency of use) 
contact your chimney sweep (elongate 

chimney/draught metering) 

incorrect use of the combustion air 

supply lever 

please operate air lever according to user's 

instructions (if secondary air is closed, the door 

glass soots rather fast) 

wood logs are too large 

keep to the max. fuel quantity according to user's 

instruction 

operating temperature was not 

reached 

more fuel, use dry wood (< 15 % residual moisture), 

attend air regulation 

 

stove does not get enough 

combustion air 

chimney draught not sufficient 

contact your chimney sweep (elongate 

chimney/draught metering) 

stove is sooted inside 

more fuel, use dry wood (< 15 % residual moisture), 

attend air regulation 

stove smells strongly and 

there is smoke on the outside 

surface 

 

baking phase of the varnish 

there may be some odour development during the 

first operations 

stove is dusty/dirty 

cleaning before the heating season starts! 

 

 

exhaust gas emission while 

putting more wood on the fire 

and during operation 

 

chimney draught no sufficient, flue 

pipe connection leaky 

inspect joints and seal up again if necessary 
check chimney draught, examine operating - for info 

video follow: 

http://www.austroflamm.com/de/Video/index.html 

the stove door was opened before 

the wood has burnt down to embers 

put more fuel wood into the combustion chamber 

only if there are only embers left (no more visible 

flame) 

Summary of Contents for Dexter 2.0 L

Page 1: ...Benutzerhandbuch manual manuale manuel User instructions Dexter 2 0 ...

Page 2: ...y air supply english Contents 1 Techn data 5 2 Important information 5 3 Correct operation of your stove 6 4 The most important spare parts overview 7 5 Special features 8 Guarantee 17 This instruction describes the Dexter left Fig 2 ...

Page 3: ...ve Attention stove varnish is no rust prevention Make your children aware of this particular danger and keep them at a distance from the heating unit whenever it is in operation Only burn approved fuels and materials listed in the chapter Clean Burning The burning or placing of flammable or explosive materials like empty spray cans and such like into the firebox as well as the storage of such mate...

Page 4: ...bre cement sheet Bellis board or similar with minimum of 300mm in front of 2 sides of glass Flue Connection to Heater The flue collar fitted to the unit is 5 Inner diameter is tapered from 137mm and outer diameter is 148mm The top flue connection requires either a 5 to 6 adaptor to fit within the top box or the Austroflamm Flue damper fits to the outside of the flue collar ensure the connection is...

Page 5: ... must have its own dedicated flue The active flue must be 8 for the entire length of the flue and always less than 45 degrees from the vertical Replacement room air from outside equivalent to 160cm2 must be supplied into the room Flue Outlet Positions Minimum Flue Height as per AS NZS 2918 2018 NOTE Flue exit MUST also be as high as any nearby structure within a 6m Radius AS 2918 2018 ...

Page 6: ...8 english Exter External Requirements Refer to AS NZS 2918 2018 Note All external air vents ceiling penetrations must be bird rodent proofed with permanently fixed screens Flue Collar Connection for Rear Flue ...

Page 7: ...DING CODE OR CODES o WARNING APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS NZS 4013 2014 WHERE REQUIRED BY THE REGULATORY AUTHORITY I E THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING TESTED TO AS NZS 4013 2014 o ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED ...

Page 8: ...rawer if necessary watch out for ambers Position the lever for the combustion air to the open AUF position see fig 4 Place 2 3 logs approx 1 0 kg in total crossways in the combustion chamber 1 with sufficient distance from each other min 2 cm on top of that place some softwood chippings 0 4 kg 2 and some ignition aid and light 3 see fig 3 Close the door We recommend to let the first load burn down...

Page 9: ...e 5 720427 Vertical Keramott outside 6 720424 Vertical Keramott corner 7 720425 Vertical Keramott rear 8 720426 Keramott baffle plate 1 9 720428 720473 Grate 716408 Other parts Dexter L Dexter R Keramott numbering installation instructions Description No Part number Dexter L Part number Dexter R Door complete 13 720430 720476 Door handle 14 361089 Door glass short side 15 720433 Door glass long si...

Page 10: ...ructions if secondary air is closed the door glass soots rather fast wood logs are too large keep to the max fuel quantity according to user s instruction operating temperature was not reached more fuel use dry wood 15 residual moisture attend air regulation stove does not get enough combustion air chimney draught not sufficient contact your chimney sweep elongate chimney draught metering stove is...

Page 11: ...surface coatings lacquer glass and ceramics Conditions of the Guarantee 1 Your AUSTROFLAMM stove was installed by a certified professional and is operated in accordance with the operator s manual 2 Claims to the guarantee shall be subject to a completely filled out Guarantee Card and submittal of the original invoice issued by a certified AUSTROFLAMM sales agent IMPORTANT Our guarantee includes fr...

Reviews: