background image

Original instructions

Air series

Part D: receiving unit L

ACrs13-L (rLB)

inDex

1 Description 

 ............................................................................................................  2

Technical data  .......................................................................................................  3

Technical data sheet  .............................................................................................  3

4 Plates 

 .....................................................................................................................  4

4.1  Plates on ACRS13-L unit in a radio remote control  ..........................................  4

4.2  Plates on ACRS13-L unit in a Take & Release radio remote control  ................  4

4.3  Plates  on  ACRS13-L  unit  in  a  Multi  Units  or  Multi  Receiver                                                                                 

radio remote control  .........................................................................................  5

Light signals  ..........................................................................................................  5

5.1  POWER LED (green)  .......................................................................................  5

5.2  ENABLE LED (green)  ......................................................................................  5

6 Operation 

 ...............................................................................................................  6

6.1  Electronic module  ............................................................................................  6

6.2  DIP switches  ....................................................................................................  6

6.3  Internal light signals  .........................................................................................  6

6.4  Command outputs  ............................................................................................  6

Malfunction signalled by the receiving unit  ........................................................  7

AUTEC

LIRLBE00-03

Summary of Contents for Air ACRS13-L

Page 1: ...trol 4 4 2 Plates on ACRS13 L unit in a Take Release radio remote control 4 4 3 Plates on ACRS13 L unit in a Multi Units or Multi Receiver radio remote control 5 5 Light signals 5 5 1 POWER LED green 5 5 2 ENABLE LED green 5 6 Operation 6 6 1 Electronic module 6 6 2 DIP switches 6 6 3 Internal light signals 6 6 4 Command outputs 6 7 Malfunction signalled by the receiving unit 7 AUTEC LIRLBE00 03 ...

Page 2: ...plate D Identification plate E Cable gland A Electronic module and address key B DIP switches C Internal light signals D STOP outputs E SAFETY outputs F STOP contacts protection fuses G SAFETY contacts protection fuses H Connector for power supply unit K Power supply protection fuse J Command outputs ...

Page 3: ... mm B 106 mm C 82 mm D 213 5 mm 3 Technical data sheet The technical data sheet contains the wiring diagram showing the connection between the receiving unit and the machine It also contains the transmitting unit configuration and shows the matching between commands sent and machine functions movements Each technical data sheet must be filled in checked and signed by the installer who is responsib...

Page 4: ... the receiving unit MODEL TYPE and main receiving unit technical data marking and possible radio remote control marks 4 2 Plates on ACRS13 L unit in a Take Release radio remote control Plate Position Content radio remote control identification plate On the cover of the receiving unit Radio remote control serial number S N bar code and manufacturing year technical data plate On the cover of the rec...

Page 5: ... N and a bar code technical data plate On the cover of each receiving unit MODEL TYPE and main receiving unit technical data marking and possible radio remote control marks 5 Light signals 5 1 POWER LED green The POWER LED indicates the status of the receiving unit The POWER LED Meaning is off The receiving unit is not powered is on Receiving unit is powered 5 2 ENABLE LED green The ENABLE LED ind...

Page 6: ... key 6 2 DIP switches DIP switch 1 is used to set the frequency band DIP switch 2 shall always be set in the OFF position do not modify it 6 3 Internal light signals The activation of each relay on the mother board is signalled by an LED near the relay 6 4 Command outputs The data sheet contains information regarding the correspondence between the commands sent by the transmitting unit and the rel...

Page 7: ...machine Make sure that power supply wires are correctly connected and that the power supply value is within the limits specified in the technical data Check the power supply protection fuse and if needed replace it The POWER LED is steady and the ENABLE LED blinks once every 5 seconds The transmitting and receiving unit do not communicate Start up the radio remote control The POWER LED is steady a...

Page 8: ......