en/TA-11-ALM-6040/10040FL
pag.: 22
USER /
INSTALATION
MANUAL
4-POST HD
ISSUED 26-05-04
A L M - 6 0 4 0 F L
A L M - 1 0 0 4 0 F L
AUTEC Hefbruggen bv
Industrieterrein IJsselveld, Vlasakker 11, 3417 XT MONTFOORT, The Netherlands
Tel: +31 348 477000 Fax: +31 348 475104 Internet: www.autec.nl - E-mail: info@autec.nl
Place footboard
(7)
above cross pieces and carefully lower it until it touches them; checking that the alignment
plugs fit properly
(15)
. Re-fit the two plates
(10)
, tighten screws
(11)
again. Lubricate the groove with grease
or heavy oil, insert joints (14) and tasten them with the screws
(13)
.
W A R N I N G :
JOINTS MUST BE INSERTED MANUALL Y:
turn bar
(12)
just enough to allow an easy fitting. Re-fit the cases
(9)
, fasten them with the appropriate
screws. Lead the gasket and the cable from the cross piece
(1)
into the welded tube on the footboard. Remove
the cover of the derivation box
(16)
where the cross piece cables enter
(2)
, pass the cable from the footboard
into the gasket attached to the derivation box. Lead the gasket with cable inside into the footboard tube and fas-
ten the box
(16)
to the footboard
(8)
. Connect cables by matching the numbers. Mount the cover of the box.
Remove restraint plates
(10)
from footboard
(8)
by loosening the screws
(11)
. Place the footboard between
the posts and lower it until it rests on the cross pieces at a distance of approx. 1200 mm from the footboard
(7)
. Then re-fit the plate
(10)
and tighten screws
(11)
again.
fig. 14