LIUPJQ001_eng-00
AUTEC
28
When using the cable control, the working features of the Radio Remote Control and of the
Take & Release Radio Remote Control (i.e. the meaning of actuators and the Data Feedback
function) do not change.
8.16.2 Operation
Before starting to work, make sure that the cable and the corresponding
connectors are intact.
Work organisation, Machines' position, passages, etc. shall be planned so
as to avoid that the cable control 's cable may be damaged by moving trolleys
or by the ongoing operations.
Do not use the cable control's cable to lift the Transmitting Unit.
Lay the cable control's cable in such a way as to avoid that it is squashed or
strained by People or objects. Avoid contact with sharp or cutting objects
that can cut the cable's protective sheath.
The cable control cannot be used if the Radio Remote Control is installed on
a Machine that controls loads that are not isolated from an AC power supply
or from a DC power supply higher than 30V .
Using the cable control at the same time as the waist belt or the shoulder
harness means that there is a physical connection between the User and the
Machine: therefore, the User must constantly check that the Machine's
movements, especially in case of loss of control (by way of example: risk of
overturning, of cable dragging by other Machinery), do not cause hazards. In
such situations, the User must pull out the belt or open it by unfastening its
buckle(s).
The cable control must only be connected and disconnected when the Transmitting
Unit is off.
When you finish working with the cable control, disconnect the cable from the
Transmitting Unit and from the Machine, and protect the connectors with their caps.
Follow this procedure to control the Machine with the cable control:
1. Power on the Receiving Unit respecting the voltage limits provided in the technical data (see
"Part D" of the Manual). The POWER LED illuminates.
2. Make sure that the battery is inside the Transmitting Unit and leave it there even though the
power supply comes from the Receiving Unit via the cable control. The battery is not, in any
case, recharged through the cable control: it can only be recharged through its appropriate
battery charger provided together with the system.
Summary of Contents for DYNAMIC+P Series
Page 2: ......
Page 6: ...LIUPJQ001_eng 00 AUTEC ...
Page 34: ...LIUPJQ001_eng 00 AUTEC 34 9 3 2 Shoulder harness Assembly 1 2 1 2 3 3 4 5 6 ...
Page 35: ...LIUPJQ001_eng 00 AUTEC 35 7 8 9 ...
Page 43: ...LIUPJQ001_eng 00 AUTEC 43 ...