background image

2

LIRPDE00-03

Description

AUTEC - Air series

1 Description

C

B

A

H

G

J

SERIAL N.      XXXXXX

MANIF. DATE  XXXX

RADIO MODULE

POWER SUPPLY

AIRRT32NM

45-400V   ±10%(0.3A)50-60Hz    

FREQUENCY                  

433.050-434.790MHz

N12335

FREQUENCY                                          915-928MHz

- Prima dell'accensione leggere il manuale d’uso. -  Attenersi alle norme di sicurezza.

- Togliere l’alimentazione e attendere 10 secondi in caso di apertura. 

- Before switching on please read the user manual. - Adhere to safety rules.

- Disconnect power source and wait 10 seconds before opening.

D

E

F

K

A

Power supply protection fuse

B

Connector for buzzer

C

DIP switches

D

Red indicator light

e

Technical data plate

F

Identification plate

G

Electronic module and address 
key

H

STOP contacts protection fuses

J

Plug or cable gland

K

Buzzer

Technical data

Power supply  ..........................................................................................  45-400V  (0.3A)

Power supply protection fuse ............................................................  2A T 500V (5x20mm)

Antenna  .................................................................................................................. internal

STOP contacts rated current  ..........................................................................  4A (250V )

STOP contacts protection fuse  .........................................................  4A T 250V (5x20mm)

Commands rated current  ................................................................................  4A (250V )

Housing material  ..........................................................................................  PA 6 (20%fg)

Protection degree  ....................................................................................... IP65 (NEMA 4)

Weight  ....................................................................................................... 0.65kg (1.43Lb)

Summary of Contents for HACRP8

Page 1: ... a Take Release radio remote control 4 4 3 Plates on HACRP8 unit in a Multi Units or Multi Receiver radio remote control 5 5 Warnings for installation 5 5 1 Mounting and fastening the receiving unit in the best position 5 5 2 Positioning the antenna 6 5 3 Wiring 6 6 Light signals 6 7 Operation 7 7 1 Electronic module 7 7 2 DIP switches 7 7 3 Command outputs 7 8 Malfunction signalled by the receivi...

Page 2: ...re to safety rules Disconnect power source and wait 10 seconds before opening D E F K A Power supply protection fuse B Connector for buzzer C DIP switches D Red indicator light E Technical data plate F Identification plate G Electronic module and address key H STOP contacts protection fuses J Plug or cable gland K Buzzer 2 Technical data Power supply 45 400V 0 3A Power supply protection fuse 2A T ...

Page 3: ...re l alimentazione e attendere 10 secondi in caso di apertura Before switching on please read the user manual Adhere to safety rules Disconnect power source and wait 10 seconds before opening SERIAL N XXXXXX MANIF DATE XXXX RADIO MODULE POWER SUPPLY AIRRT32NM 45 400V 10 0 3A 50 60Hz FREQUENCY 433 050 434 790MHz N12335 FREQUENCY 915 928MHz Prima dell accensione leggere il manuale d uso Attenersi al...

Page 4: ...s must always reflect the wiring indicated in the technical data sheet 4 Plates 4 1 Plates on HACRP8 unit in a radio remote control Plate Position Content radio remote control identification plate On the cover of the receiving unit Radio remote control serial number S N bar code and manufacturing year technical data plate On the cover of the receiving unit MODEL TYPE and main receiving unit techni...

Page 5: ...a marking and possible radio remote control marks 5 Warnings for installation 5 1 Mounting and fastening the receiving unit in the best position The following warnings complete and or replace the corresponding information in the paragraph about part A The HACRP8 receiving unit if equipped with a plug may be directly connected to the electrical panel of the machine by fastening it through the locki...

Page 6: ...the outputs of the receiving unit shall not exceed 250V Within the HACRP8 receiving unit the STOP circuit has two contacts connected in series and it provides a common to all commands Within the HACRP8 receiving unit the SAFETY relay is always connected in series to the common of the movement commands therefore the rest position of actuators is always protected from unintended movements These conn...

Page 7: ... persists after the suggested solution has been carried out contact the support service of the machine manufacturer Signals Possible reason Solutions The red indicator light is off Wrong or no power supply Correctly plug in the connecting plug between the radio remote control and the machine Make sure that power supply wires are correctly connected and that the power supply value is within the lim...

Page 8: ......

Reviews: