6
LIRPDE00-03
Light signals
AUTEC - Air series
5.2
Positioning the antenna
The following warnings complete and/or replace the corresponding information in the
paragraph about part A.
The HACrP8 receiving unit is not set up for the use of an antenna extension
kit.
5.3 Wiring
The following warnings complete and/or replace the corresponding information in the
paragraph about part A.
The metal housing of the plug connecting the HACrP8 receiving unit from
the electrical panel of the machine must be wired to the earth connector so
as to avoid hazards relating to electrical safety.
Voltage in the outputs of the receiving unit shall not exceed 250V .
Within the HACrP8 receiving unit, the sTOP circuit has two contacts
connected in series and it provides a common to all commands.
Within the HACrP8 receiving unit, the sAFeTY relay is always connected
in series to the common of the movement commands: therefore the rest
position of actuators is always protected from unintended movements.
These connections cannot be modified.
in order to supply the receiving unit with 400V power, connect it to a
230/400V three-phase power line (230V line-to-neutral voltage; 400V
line-to-line voltage).
6
Light signals
The red indicator light blinks once every 5 seconds
: the receiving unit is powered.
The red indicator light blinks fast
: the unit is ready to receive the commands sent by the
transmitting unit.
Summary of Contents for HACRP8
Page 8: ......