7 Maintenance
- 23 -
LIMM&SA0-00.fm
7
MAINTENANCE
These instructions do not in any case substitute the norms and laws that regulate work safety,
nor do they limit the responsibility of the purchaser and user of the radio remote control.
All control and maintenance actions carried out on the radio remote control must be verified and
recorded by the person in charge of carrying out maintenance on the machine.
Before carrying out maintenance, it is recommended to replace the battery with
a charged one and to ensure the efficiency of the starting keyswitch.
After each maintenance action, always make sure that commands sent by the
transmitting unit only activate the corresponding expected operations.
Routine maintenance carried out as described in this manual is fundamental for
using the radio remote control safely.
7.1
Routine maintenance
Routine maintenance consists of operations carried out to maintain (through verifica-
tions, restoration, programmed replacements) the use and working conditions fore-
seen by Autec when the product is placed on the market.
Special applications may need more specific routine maintenance actions to be carried out at
different periods.
All given instructions must be followed correctly each time the machine and the radio
remote control are put into service.
If problems are noted while carrying out routine maintenance, disable the sys-
tem “radio remote control” and follow the indications provided in
chapter 9.
Transmitting
units
Every day:
1.remove dust or accumulations of other material from the transmitting unit: never use solvents
or flammable/corrosive materials to clean, and do not use high pressure water cleaners or
steam cleaners
2.store the transmitting unit in clean and dry areas
3.make sure that the gaskets, bellows and caps of the joysticks, selectors and pushbuttons are
intact, soft and elastic
4.make sure that the battery housing and the battery contacts are always clean
5.check structural integrity of the transmitting unit
6.make sure that the panel symbols can be easily recognised and replace the panel if necessary
7.check that the identification plate is readable and not damaged
8.make sure that the STOP pushbutton works properly before using the radio remote control
9.check that the selector 1/1+2/2 works properly before starting to work.
Receiving
units
Every 3 months:
1.remove dust or accumulations of other material from the receiving unit: never use solvents
or flammable/corrosive materials to clean, and do not use high pressure water cleaners or
steam cleaners
2.check structural integrity of the receiving unit
3.check that the internal wiring of the receiving unit is intact and connected
4.make sure that the panel symbols can be easily recognised and replace the panel if necessary
5.check that the identification plate is readable and not damaged
Electrical
operation
Every six months:
1.make sure that all the relay contacts of the receiving unit operate correctly, and check that
the contact closes when the corresponding manoeuvre is enabled and opens when the ma-
noeuvre is disabled
2.check the correct correspondence between the commands that are sent and the manoeuvres
that are carried out
3.check that the contact for the SAFETY relay is open when no movement command has been
sent. This is safety critical maintenance. it is necessary to keep a record (date, signature,
Component
Interval
Daily
Every 3
months
Every 6
months
Every 12
months
Transmitting units
X
Receiving units
X
Electrical operation
X
External
electrical conductors
X