9 Diagn
ostics
- 29 -
LIMM&SA0-00.fm
9.2
Receiving unit diagnostics
If diagnostics described in paragraph 9.1 has been carried out with the transmitting unit UTX-S
of a “Master/Slave” system, carry out the diagnostic procedure with the receiving unit URX-2.
If diagnostics described in paragraph 9.1 has been carried out with the transmitting unit UTX-M
of a “Master/Slave” system, carry out the diagnostic procedure twice, one with the receiving unit
URX-1 only, the other with the receiving unit URX-2 only.
If, on the contrary, diagnostics of paragraph 9.1 has been carried out with a transmitting unit
of a “Master/Master” system, carry out diagnostic procedure twice, one with the receiving unit
URX-1 only and another one with the receiving unit URX-2 only.
(*) If the address keys (E16SCHEU_) have been replaced, do the following:
- check that the transmitting unit is off and the receiving unit is powered
- switch on the transmitting unit
- press the START pushbutton without releasing it for at least 5 seconds.
Is the POWER ENABLE
signal light switched off?
Is the connecting plug
between the radio remote
control and the machine
connected correctly?
Correctly insert
the connecting plug
and start the
radio remote control.
Is the POWER ENABLE
signal light blinking?
CALL TECHNICAL
ASSISTANCE
YES
YES
NO
NO
YES
NO
If the address keys have
been changed it is neces-
sary to reconfigure the re-
ceiving unit (*). Does the
machine start?
Replace blown fuses.
Connect to power source
and switch on radio re-
mote control. Does the
machine start?
NO
Remove power from the
receiving unit. Check fus-
es. Are they intact?
NO
Check the power supply
connections.
YES
Change the frequency set
in the radio modules (see
paragraph 1.7)
.
Does the machine start?
NO
NO