Operating voltage ................................................... 7.5-15 V

Current consumption in the standby mode ............ 5 mА

Nominal/peak communication current:

TOR 02 ................................................................. 1А / 2А

TOR 20 ............................................................. 10А / 20А

Contents of the set

TOR module 

 

  

 

      1 pcs.

Operating manual  

 

 

      1 pcs.

Packing   

 

 

 

      1 pcs.

Made in Russia

Manufacturer: LLC «DMA Group»

C-RU.АЛ14.В.10097

The developer and the manufacturer retain the right to make technical 

updates not specified in this operating manual. To learn more visit our 

web-site:

http://author-alarm.com

Summary of Contents for TOR

Page 1: ...OPERATING MANUAL ...

Page 2: ...version 803 1 ...

Page 3: ...3 General information 4 Engine locking 4 Locking algorithm 4 Locking scheme 5 Device installation 5 Wiring map 6 Connecting IGLA and TOR 7 Specifications 9 Contents of the set 9 TABLE OF CONTENTS ...

Page 4: ...nd Anti Hi Jack option for car without digital locking of an operating engine Locking algorithm TOR locking activates at attempt of driving without authorization or in Anti Hi Jack mode when a CAN bus lacks data required for TOR operation or the IGLA system digital locking has failed In other cases the activation of the additional circuit is impossible Locking is released by entering a PIN code of...

Page 5: ... black wires or by contact closure between the green and the white black wires when the ignition is on or the engine is started Device installation The status output orange wire is for connection of siren and other equipment GPS alarm system for example When the locking is activated the output has the negative potential that disappears in 5 seconds or right after the locking is deactivated Negativ...

Page 6: ...r supply 6 Yellow Ignition lock required for connecting a locking relay 7 Orange Status output for the connection of the external devices max 250 mA 8 Purple Normally closed contact 9 Green Normally opened contact 10 White black brown Relay common contact 2 5 4 3 1 8 10 9 Status output Blocking circuit Ignition lock CAN bus ...

Page 7: ...e authorization is successful enter the current PIN code once again while pressing the accelerator pedal as far as it can go ATTENTION If the current PIN code include Slight touch on accelerator pedal it is necessary to enter the PIN code once again after the authorization and then press the accelerator pedal as far as it can go Then perform item 2 2 Connect TOR relay to the wiring according the w...

Page 8: ...rrect operation of TOR module 1 Turn off the ignition 2 Activate the standard alarm system 3 Deactivate the security system 4 Disconnect the power supply form IGLA system 5 Start the ignition and attempt to drive If TOR module locks the engine the module operation is correct Otherwise repeat the procedure of IGLA and TOR connection Dependingonthefirmwareofthe device itispossiblethesignallingcontin...

Page 9: ...02 1А 2А TOR 20 10А 20А Contents of the set TOR module 1 pcs Operating manual 1 pcs Packing 1 pcs Made in Russia Manufacturer LLC DMA Group C RU АЛ14 В 10097 The developer and the manufacturer retain the right to make technical updates not specified in this operating manual To learn more visit our web site http author alarm com ...

Page 10: ...mage or absence of a factory trade label Only items in complete set and with the original packing are taken for warranty repair Absence of packing is regarded as noncompliance with transportation rules The warranty does not apply to the damage incurred to another equipment operating together with this device Item model ________________ Sale date ______ ____ ________ The contents of delivery ___ fu...

Page 11: ...11 ...

Page 12: ...Supported Cars List App ...