19
P/N 240009735, Rev. G [09/30/2016]
11 - FIELD ASSEMBLY
1.
Install oil burner� Follow burner manufacturer
specific instructions for installation.
• Check oil nozzle in burner for size, angle and type,
inspect electrode settings, check head setting,
check air band and air shutter settings� See “Oil
Burner, Nozzle, & Air Settings” �
• DO NOT install burner without gasket� Place oil
burner gasket on face of burner swing door with 4
burner flange bolts installed part way.
•
Align round part of key hole slots of burner flange
with burner door bolts� Turn burner to lock in place�
• Tighten all 4 cap screws using diagonal sequence�
• Plug burner power cord into burner harness�
•
Attach flexible oil hose included in parts box.
• Connect burner quick connect to corresponding
High Limit Control harness� See Figure #22�
2.
Follow circulator manufacturer specific instructions
included with circulator if appropriate�