OPERATING MODES
Once the door is operating correctly the desired mode can be selected:. There are
five modes available:
i.
Automatic mode (green LED)
–
the door will open when a sensor is triggered
and close after the preset dwell time has elapsed.
ii.
Hold open mode (Blue LED)
–
door will open and remain open until another
mode is selected.
iii. Lock mode: door will close and remain closed until another mode is selected
through remote system, if an e-Lock is connected.
iv. Pet mode (Yellow LED)
–
Will open the door to the pet opening width when
pet sensor is triggered and close after the preset dwell time has elapsed.
v. Manual mode: the door can be manually operated; the system will not drive
the door.
vi. This option is for function select.
•
Once the settings are confirmed the drive unit can be powered on. Switch the
main isolator switch on the left side of the controller to the down (on) position.
Caution: the door will begin to move without warning!
•
After a short delay, the LED display will begin to flash, and door will begin close
slowly. If the door starts to open when first powered up, turn dip switch 1 to the
opposite position (leave power on), the door will then change direction to the
closing position.
•
During self calibration process, once the door has fully closed, the door will then
slowly slide to the open position, then close slowly back to the closed position
with a small increase in speed. The door will then open in a fast speed once,
then closed. Once the lights on the control panel stop blinking and turns on solid
green, learn cycle is successful. The Multi-Controller has now memorized the width
of the door opening, the weight and friction of your door while sliding. And now
knows the individual power to operate your door smoothly and reliable. Your Multi-
controller is now ready to be used.
SPEED ADJUSTMENT
Adjustment of Speed:
Opening Speed: 0.4in to 1.6in/second / 10 to 41 cm/second
Closing Speed: 0.5in to 0.8in/second / 12 to 22 cm/second
Slam Mode:
Opening Speed under 80%, Open and Close speed is same.
Opening Speed higher than 80%, Closing speed is half of opening.
Without rubber:
Opening Speed lower than 50%, Open and Close speed is same.
Opening Speed higher than 50%, Closing speed is half of opening.
Opening time: 0 to 20 seconds (Adjustable)
Learning button: Learning button of remote or wireless push button, added and delete
remote process
Learning LED: Remote Learning Indicator
20
19