7-17
CONNECTION OF SERVICES
COMMON FAULT TABLE
Fault
Possible Cause
Proposed Fix
No 230 volt
Connecting lead between
Check and connect lead as per page 7-18, note 3.
output from
the site and Leisure
Check also input connector at the base of the ED155 PSU.
PSU.
Vehicle not connected.
RCD switched off.
Reset RCD as per page 7-18, note 4.
RCD not operating
Check supply polarity; if the RCD continues to fail contact your
correctly.
dealer, as there is probably an equipment or wiring fault.
MCB switched off.
Reset MCB by switching OFF (down position) then back ON (up
position), if the MCB continues to fail contact your dealer, as there is
probably an equipment or wiring fault.
No or deficient supply
Contact site warden for assistance.
from site.
Other fault.
Contact your dealer.
Control
Control Panel has no
Check batteries and fuses, turn EC155 PSU charger switch on, and
Panel Problems.
display.
ensure mains supply is connected.
Check control panel connecting lead at EC155 PSU and behind
Control Panel.
Contact your Dealer.
12V Power turns off.
Battery save feature has operated to protect the vehicle battery and
or the Leisure battery. See page 7-15.
Engine has been started, all equipment has been disconnected to
meet EMC requirements. See page 7-18.
Observe control panel handling instructions.
Control Panel display
Control panel software may have crashed. Reboot control panel by
corrup/erratic
turning off the EC155 PSU charger switch and removing fuses 9 and 10
function.
at the EC155 PSU (2x20A fuses for leisure and vehicle batteries).
Wait 30 seconds then replace the fuses and turn the charger switch on.
(Alternatively, remove the bezel at the control panel by pulling down
in the centre at the bottom, unplug the control panel multi-way
connector, wait 30 seconds, then plug back in and reassemble.
No 230V supply.
Check all above.
Charger not switched on.
Switch charger switch on (I) position, switch will illuminate.
Battery not connected and
Install charged battery as per page 7-15.
/or charged.
No 12 volt output
Power switch on control
Turn power on at control panel.
from PSU
panel not switched to ON.
Battery flat/Battery fuse blown.
Recharge battery, check fuses, check voltage is present at battery.
Fuse blown.
Check all fuses are intact and the correct value fuse is installed as
per fuse table.
Equipment switched off/
Check equipment is switched on and connected to the 12V supply.
unplugged.
PSU overheated/auto
Reduce load on system. Allow PSU to cool down. PSU will
shutdown operated.
automatically restart when cool. See page 7-13.
Other fault.
Contact your dealer.
Pump not working.
Fuse blown.
Replace fuse.
Pump turned off.
Turn pump on by pressing the pump button at the EC155 control
panel (tap symbol).
Summary of Contents for Peugeot Kemerton
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 24: ...6 8 SAFETY SECURITY ...
Page 42: ...7 18 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 69: ...9 23 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Page 70: ...9 24 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Page 75: ...9 29 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT ...
Page 79: ...9 33 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY ...
Page 80: ...9 34 FITTED EQUIPMENT DOUBLE BED ASSEMBLY ...
Page 106: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2011 Ref 21210 ...