9-10
FITTED EQUIPMENT
Gas Lockouts
Gas lockouts must be cleared by moving the
gas switch from on position to off position
then back to the on position. The complete
sequence of switch movements must be
completed within 2.5 seconds for a lockout to
be successfully cleared. If there is air in the
gas line, eg after a gas bottle change, the
water heater may require several attempts
before it lights.
Other Lockouts
If the lockout is caused when the unit is
operated on electric, the lockout can be
cleared by moving the electric switch from on
position to off position then back to the on
position. The complete sequence of switch
movements must be completed within 2.5
seconds for a lockout to be successfully
cleared.
Note:
A cycling of the power supply to the
unit will not clear a lockout. Some gas
lockouts, eg ignition lockout will still permit
TROUBLESHOOTING
The heater is equipped with an electronic diagnostic system which will detect fault conditions
ranging from poor gas or dc supply to internal heater malfunctions. In the event of a failure, the
red light on the control panel will flash a number of times, pause, and repeat until switched off.
Count the number of flashes and refer to the table below.
Check gas supply making sure there is gas in the bottle
and no blockage in the gas line. Ensure propane is used at
temperatures below +5
°
C. Clear lockout as described
below.
Check there is water in the appliance. We recommend you
wait at least 5 to 10 minutes to allow the heater to cool
before clearing lockout as described below.
Minimum operating voltage is 10v, maximum is 15v, when
measured at the heater. Check battery voltage. If between
10v and 15v, check connections between heater and
battery. Check alternator or external battery charging. Clear
lockout as described below.
Attempt to clear lockout as shown below. If this fails,
contact a Whale Authorised Service Engineer.
Number of
flashes
Fault
Remedy
No flame
detected
Overheat
Low/high
supply
voltage
Other/
internal fault
1
3
2
5
use of the appliance in electric only
operation.
If the problem persists contact Whale
Support on 0845 217 2933
Winterising / Draining
When using the heater in winter ensure the
flue is not blocked by snow or fallen leaves
etc. When not in use, ensure the heater is
drained. This is particularly important during
the winter months as a precaution against
freezing. To drain, switch off the water pump
at either the pump switch or main switch.
Open all the hot water taps in the vehicle and
operate the drain valve fitted in the system.
The drain valve should be left in the open
position to ensure all the water drains out.
Service Support
For serviceable parts advice please contact
Whale Customer Support:
Tel: 0845 217 2933
Email: info@whalepumps.com
Summary of Contents for Peugeot Kemerton
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 24: ...6 8 SAFETY SECURITY ...
Page 42: ...7 18 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 69: ...9 23 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Page 70: ...9 24 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Page 75: ...9 29 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT ...
Page 79: ...9 33 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY ...
Page 80: ...9 34 FITTED EQUIPMENT DOUBLE BED ASSEMBLY ...
Page 106: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2011 Ref 21210 ...