9-15
FITTED EQUIPMENT
Gas Lockouts
Gas lockouts must be cleared by turning the
selector knob from gas (flame) position to ‘off’
position then back to the ‘on’ position. The
complete sequence of switch movements
must be completed within 2.5 seconds for a
lockout to be successfully cleared. If there is
air in the gas line, eg after a gas bottle
change, the space heater may require
several attempts before it lights.
Other Lockouts
If the lockout is caused when the unit is
operated on electric, the lockout can be
cleared by turning the selector knob from
electric ‘on’ position to ‘off’ position then back
to the ‘on’ position. The complete sequence
of switch movements must be completed
within 2.5 seconds for a lockout to be
successfully cleared.
Note:
A cycling of the power supply to the
unit will not clear a lockout. Some gas
lockouts, e.g. ignition lockout and combustion
air faults will still permit use of the appliance
in electric only operation. If the problem
persists contact Whale Support on +44
(0)845 217 2933.
Winterising
When using the heater in winter ensure the
flues are not blocked by snow or fallen leaves
etc. When the Space Heater is not going to
be used for a long period of time, we
recommend that the open end of the
combustion air and exhaust flue are covered
to prevent ingress of leaves etc.
Service Support
For serviceable parts advice please contact
Whale Customer Support:
Tel: +44 (0)845 217 2933
Email: info@whalepumps.com
Warranty
The Whale Space Heater is covered by a 3
year warranty.
Please complete the enclosed warranty card
and return to Whale.
For warranty details, please refer to the
Whale Website www.whalepumps.com
Note that any alteration to the appliance,
including flue components, use of non-Whale
spare parts/accessories and non-observation
of the installation and operation instructions
shall lead to cancellation of the warranty and
exclusion of liability claims and results in it
becoming illegal to use the appliance.
Specification
Nominal heat input, Gas: 2.0 kW.
Gas Consumption: 150g/h.
Nominal heat input, Electric: 2.0 kW.
Mains Electric:
Nominal voltage: 230V ac: 50 Hz.
Power options: 500 / 1000 / 2000W.
Maximum current ac: 9 Amps.
Battery Supply:
Nominal voltage: 12V dc.
Maximum current dc, gas operation: 1.7
Amps (0.01 Amps on standby).
Maximum current dc, electric operation:
2.2 Amps (0.01 Amps on standby).
Summary of Contents for Peugeot Kemerton
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 24: ...6 8 SAFETY SECURITY ...
Page 42: ...7 18 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 69: ...9 23 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Page 70: ...9 24 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Page 75: ...9 29 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT ...
Page 79: ...9 33 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY ...
Page 80: ...9 34 FITTED EQUIPMENT DOUBLE BED ASSEMBLY ...
Page 106: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2011 Ref 21210 ...