10-5
CARE OF YOUR MOTORHOME
TROUBLESHOOTING
The following are a series of fault finding charts to which you should refer in the event of
problems you may have regarding 230/12V, LPG and water. This should be used as a guide only,
and in the case of an electrical fault, where a fuse has blown or an MCB tripped out, the fault
must be located before replacing the fuse. If a fault is suspected with the LPG system, consult a
GAS SAFE registered technician.
If in doubt consult a qualified technician or your local Auto-Sleeper dealer.
12V TROUBLESHOOTING CHART
Symptom
Cause
Remedy
Habitation 12V does not
Main 20A fuse blown
Check/Replace
operate
Battery Discharged
Recharge
Switch on control panel in off
Switch to on
position
Vehicle ignition ‘on’
Switch ‘off’ ignition
Habitation battery not
Main 20A fuse blown
Check/Replace
charging
Relay fault
Refer to dealer
Contacts dirty/loose on
Clean and check for tightness
battery terminals
Poor earthing
Check earthing to chassis point
Battery does not hold its
Failed battery
Check cells with hydrometer
charge
change electrolyte if necessary
Current being drawn
Check all appliances are off
when not in use
Battery discharges over a
Poor battery cell condition
Check cells with hydrometer
short time with appliances
Failed battery
Change battery
operating
Battery not fully charged
Fully recharge battery
No power to one or more
Circuit fuse blown
Find fault and replace fuse with
12V appliances
same rating
Lights dull/only one tube
Low battery charge
Check battery
illuminating
Faulty light unit/tube
Replace/Check
Water pump not operating
Switch on panel ‘off’
Switch it ‘on’
Pressure switch on pump not
Refer to dealer
operating
Fuse 4 blown
Find fault and replace fuse with
same rating
No power on 12V socket
Fuse 9 blown
Find fault and replace fuse with
outlet
same rating
12V plug incorrectly
Check plug
connected/wired
Summary of Contents for Peugeot Kemerton
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 24: ...6 8 SAFETY SECURITY ...
Page 42: ...7 18 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 69: ...9 23 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Page 70: ...9 24 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Page 75: ...9 29 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT ...
Page 79: ...9 33 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY ...
Page 80: ...9 34 FITTED EQUIPMENT DOUBLE BED ASSEMBLY ...
Page 106: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2011 Ref 21210 ...