Installation Guide
P. 29
Diagnostics
via
parking
lights
Diagnostic
table
for
shutdown.
Parking lights flashes
Cause
1
•
Runtime has expired.
2
•
Shutdown by remote.
•
Ready mode is activated.
3
•
Failed start.
4
•
Brake shutdown.
10
•
Hood shutdown.
Flash for 30sec
•
Panic mode
Flash for 60sec
•
Alarm triggered
Diagnostic
table
for
start
failure.
Parking lights flashes
Cause
0
•
Ignition is active
1
(Manual transmission only)
•
Ready mode is not activated.
•
Tach signal is not learned.
1 slow
Î
2 quick
•
The system is set to valet mode.
3
(Automatic transmission
only)
•
The parking brake is active.
•
Yellow loop is connected.
4
•
Brake wire is active
6
•
A tach signal is detected before Ignition.
10
•
Hood wire is active.
Note: The installer can also use the PRG-1000 to diagnose shutdown and remote start failures.
Refer to the PRG-1000 manual guide.
Parking
lights
flash
summary
table
Parking lights flashes
Description
1
•
Doors locked.
•
Trunk released.
•
Start signal received from the remote.
2 slow
•
Power OFF
Î
ON; transmission is set to automatic.
2 fast
•
Doors unlocked
•
Valet mode is deactivated
3 slow
•
Runtime is extended.
3 fast
•
Valet mode activated.
4 fast
•
Power OFF
Î
ON; transmission is set to manual.
•
Enter multi speed tach programming
•
Enter time delay adjustment in virtual tach system.
5 fast
•
Tach signal is learned successfully.