*Please set the sensor away from water outlet and direct light to
avoid bubble interference or malfunctions.
**If there is still water dripping, please lower the level of reservoir, or
adjust the tube outlet higher, or purchase an Anti-Siphon Valve to
connect it to the tube outlet.
Installation
1. Mount the square dual sensor on the tank/sump with the magnet,
and adjust the lower sensor to the desired water level.
*
2.
Fix the AQUA Lifter Pump Holder on the tank/sump and mount the
AQUA Lifter Pump.
3. Plug the pre lter into the tubes and keep it higher than the max.
level of the reservoir. Fix the tube with the AQUA Lifter Pump
Holder and connect it to the inlet of pump.
4.
Connect the water outlet tube and x it with the AQUA Lifter Pump
Holder.
5.
Connect the pump and the power adapter with the controller.
6.
Connect power and do one-time lling to check there is no water
dripping from reservoir to tank/sump (forward siphon) after the
pump stops.
**
7.
Unplug and plug the power adapter back in for reset.
3
Tank/Sump
Pre lter
Pre lter :
The Pre lter must
be installed before
the inlet of the
diaphragm pump.
Water Inlet
Reservoir
Optical Level Sensor
Power
Anti-Siphon
Pressure 1 feet
max. level