Smart AWC touch uses QST for real-time protection against any failure situation.*
The controller will give an audible and visual alert when any one of the following
situations occurs.
For ATO
: Any refilling time is 3 times longer than the first refilling time.
For example, if the first refilling time is 10 sec, the controller will give an alert
when any refilling time is over 30 sec.
For AWC
: Any draining time or refilling time is 3 times longer than the first one.
For example, if the first draining or refilling time is 20 sec, the controller will give
an alert when any draining or refilling time is over 60 sec.
*1. No security time control for the first refilling and draining.
2. The minimum security time for ATO refilling is 10 sec, while the minimum security time for
AWC draining or refilling is 20 sec.
Reset : Holding for at least 8 sec is the only way
to clear the QST memory (the first draining time and
the first refilling time).
After reset, please unplug and replug the power cable.
Quick Security Technology (QST)