electrical systems
56
ec400 power control system
2 USInG THE SySTEM
2.1 Power Supply Unit -
Component Layout
The PSU is located in the bed box area.
2.2 Activating the System
The EC400 system has a shutdown feature
that can be used when the vehicle is in
storage. This allows the leisure electronics
to be turned off when not required to save
battery power. When in the off state the
alarm and tracking system supplies are still
active, all other supplies are turned off.
Before using the system please ensure
the system ‘Shutdown switch is in the on
position (button in).
2.3 Connecting to the Mains 230V
supply and Safety checks
For your safety it is IMPORTANT that you
follow these connections instructions each
time your Leisure Vehicle is connected to
a mains supply. This section assumes that
the system is complete and that a Leisure
battery has been installed (see 3.4).
A)
Ensure suitability of the Mains Supply.
Your Leisure Vehicle should only be
connected to an approved supply that
meets the requirements of BS7671
or relevant harmonised standards.
In most cases the site warden will
hold information regarding suitability
of supply. If using a generator
you also need to comply with the
requirements / instructions supplied
with the generator. Please note that
some electronic generators may
not be compatible with your leisure
system. Further generator operational
information is contained elsewhere in
this manual.
B)
Switch the PSU Power Converter OFF.
Locate the green ‘Charger’ power
switch on the PSU and ensure the
switch is in the off position (button
out) before connection to the mains
supply.
C)
Connect the Hook-up Lead. Firstly
connect the supplied hook-up lead
(orange cable with blue connectors) to
the Leisure Vehicle and then connect
to the mains supply.
D)
Check Residual Current Device
operation. Locate the RCD within the
PSU and ensure the RCD is switched
on (lever in up position). Press the
‘Test’ button and confirm that the
RCD turns off (lever in down position).
Switch the RCD back to the on
position (lever in up position). If the
test button failed to operate the RCD
see section 3.10.
E)
Check Miniature Circuit Breakers.
Locate the MCB’s within the PSU
(adjacent to the RCD) and ensure they
are all in the on (up) position. If any
MCB’s fail to ‘latch’ in the on position
see section 3.10.
F)
Turn the PSU ON. Locate the black
‘Shutdown’ button and ensure it is
in the on position (press button in).
Locate the green ‘Charger’ switch on
the PSU and turn to the on position
(press button in). The charger switch
will illuminate when turned on.
G)
Check correct Polarity. Locate the
‘Reverse polarity’ indicator on the
PSU and ensure that the indicator is
NOT illuminated. If the indicator is
illuminated see section 3.10.
H)
Check operation of equipment. It is
now safe to operate the 12v and 230v
equipment.
Summary of Contents for 2012 Van Conversion Range
Page 1: ...2012 owners handbook van Conversion range ...
Page 4: ...2 co nt e n ts ...
Page 6: ...4 wa rr an t y inf or mat io n ...
Page 25: ...e n r ou t e 23 en route Panel van spare wheel detail 24 Cruise Control 24 ...
Page 34: ...sa f e t y se curity 32 safety security ...
Page 35: ...a rriva l at s it e 33 arrival at site Positioning the Motorhome 34 ...
Page 132: ...e q u ip me nt de ta il s 130 ...
Page 140: ...138 u se fu l inf or matio n ...
Page 144: ...u se fu l inf or matio n 142 useful information ...
Page 145: ...u se f u l inf or mat ion 143 useful information ...
Page 148: ...u se fu l inf or matio n 146 ...
Page 149: ...u se f u l inf or mat ion 147 ...
Page 150: ...u se fu l inf or matio n 148 ...
Page 152: ...u se fu l inf or matio n 150 ...