equipment det
ails
76
8. Only pressure control equipment that
complies with EN 12864 (in vehicles) and EN
ISO 10239 (for boats) with a fixed delivery
pressure of 30 mbar must be used for the
gas system. The flow rate of the pressure
control device must correspond to at least
the maximum consumption of all devices
installed by the system manufacturer.
For vehicles we recommend the Truma
SecuMotion gas pressure regulator and the
Truma DuoComfort automatic changeover
valve for the two-cylinder system.
At temperatures of around 0°C or less the
gas pressure regulator and the changeover
valve must be operated using the EisEx
de-icing system.
Controller connecting hoses that meet national
regulations must always be used in the
respective country for which the equipment
is destined. These hoses must be checked
regularly for brittleness. Winter-proof special
hoses must always be used if the equipment is
operated during the winter.
If the pressure regulator is exposed to weather
conditions – especially on trucks – always make
sure to protect the regulator using the Truma
protective cover (standard accessory in truck
attachment kit).
Technical data
determined in accordance with EN 624 or
Truma test conditions
Type of gas:
Liquid gas (propane/butane)
operating pressure:
30 mbar (see data plate)
Rated thermal output
High setting: 2400 W
Low setting: 1200 W
Gas consumption
High setting: 200 g/h
Low setting: 100 g/h
Air flow rate
High setting: approx. 78 m3/h
Low setting: approx. 49 m3/h
Current input at 12 V
High setting: 1.1 A
Low setting: 0.6 A
Current input at 24 V
High setting: 0.7 A
Low setting: 0.4 A
Standby:
0.01 A
Weight:
approx. 4.7 kg
Declaration of conformity:
The Trumatic E 2400 has been tested by the
DVGW and complies with the gas equipment
directive (90/396/EEC) and the other applicable
EC directives. The following CE Product Ident.
No. is available for EU countries:
CE-0085AP0008.
The heater complies with heater directive
2001/56/EC and supplements 2004/78/EC
and 2006/119/EC and bears the type approval
number: e1 00 0144.
The heater complies with vehicle engine
interference suppression directive 72/245/EEC
with supplements 2004/104/EC and 2005/83/
EC, and bears type approval number:
e1 03 2605.
The heater complies with EMC directive
89/336/EEC and low voltage directive
72/23/EEC.
trumatic lpg heater
Summary of Contents for 2012 Van Conversion Range
Page 1: ...2012 owners handbook van Conversion range ...
Page 4: ...2 co nt e n ts ...
Page 6: ...4 wa rr an t y inf or mat io n ...
Page 25: ...e n r ou t e 23 en route Panel van spare wheel detail 24 Cruise Control 24 ...
Page 34: ...sa f e t y se curity 32 safety security ...
Page 35: ...a rriva l at s it e 33 arrival at site Positioning the Motorhome 34 ...
Page 132: ...e q u ip me nt de ta il s 130 ...
Page 140: ...138 u se fu l inf or matio n ...
Page 144: ...u se fu l inf or matio n 142 useful information ...
Page 145: ...u se f u l inf or mat ion 143 useful information ...
Page 148: ...u se fu l inf or matio n 146 ...
Page 149: ...u se f u l inf or mat ion 147 ...
Page 150: ...u se fu l inf or matio n 148 ...
Page 152: ...u se fu l inf or matio n 150 ...