sooner you can use the PLC Database File Editor to add the break command
or do the following in the Module Terminal Information table.
HP?WA-D;TERM_07\SPECIAL=BREAK
Triggering for re-prompt of I/O address
Some modules include inputs and outputs. You can trigger AutoCAD Electrical
to prompt for a new beginning address number when the parametric build
flips from inputs to outputs or vice versa. Add "\SPECIAL=ADDR_OUT" on
the line where you want a re prompt for a new output address or add
"\SPECIAL=ADDR_IN" if you want a reprint for a new beginning input address.
Including unused terminals
Some modules may have terminals that are not used. Unused terminals are
skipped by default, resulting in a compact representation of the module. You
can set up the PLC database file to optionally show unused terminals by adding
"\SPECIAL_INCLUDE" and "\SPECIAL_EXCLUDE" in the Module Terminal
Information table.
Special spacing
Normally when AutoCAD Electrical generates a PLC module, it uses the current
rung spacing for I/O and wire connection point spacing. You can override
this by using the "\SPECIAL=SPACINGFACTOR=<val> in the Module Terminal
Information table. When AutoCAD Electrical sees this on an I/O point or wire
connection entry line, it uses a factor of the rung spacing. For example, a
"\SPECIAL=SPACINGFACTOR=0.5" for a given I/O or wire connection entry
flags AutoCAD Electrical to insert this point down 0.5 rung spacing instead
of a full rung spacing. A value of 1.5 inserts the point down an extra half run
spacing than normal while 0.0 inserts the I/O point at the same location as
the preceding one.
For example, the following four lines in a parametric data file inserts four
points spread out over four ladder rung spaces:
HP?WA-D;TERM_=01
HP?W--;TERM_=COM
HP?W--;TERM_=VDC
HP?WA-D;TERM_=02
If you want the two middle terminal symbols to be grouped together into one
rung space instead of taking up two spaces, edit the file to read:
HP?WA-D;TERM_=01
HP?W--;TERM_=COM;\SPECIAL=SPACINGFACTOR=0.5
Overview of the PLC database file | 229
Summary of Contents for 22505-051400-9000 - AutoCAD Electrical 2008
Page 1: ...AutoCAD Electrical 2008 User s Guide February 20 2007 ...
Page 4: ...1 2 3 4 5 6 7 8 9 10 ...
Page 106: ...94 ...
Page 228: ...216 ...
Page 242: ...HP W TERM_ VDC SPECIAL SPACINGFACTOR 0 5 HP WA D TERM_ 02 230 Chapter 5 PLC ...
Page 294: ...282 ...
Page 564: ...552 ...
Page 698: ...686 ...
Page 740: ...728 ...
Page 814: ...802 ...
Page 1032: ...1020 ...
Page 1134: ...1122 ...
Page 1168: ...1156 ...
Page 1177: ...Insert P ID Component Overview of pneumatic tools 1165 ...
Page 1198: ...1186 ...
Page 1269: ...AutoCAD Electrical Command In this chapter AutoCAD Electrical Commands 20 1257 ...
Page 1304: ...Z zip utility 82 1292 Index ...