defined inside of AutoCAD Electrical for each component category are
processed in the project database and subsequent reports.
Table style cross-referencing updates
Tabular cross-referencing styles now function at the same level as graphical
and text styles. Create customizable tables, updated your drawing in real-time
and benefit from increased flexibility with the way you display
cross-referencing information.
Cross-reference updates
Cross-reference settings are now supported at the project, drawing, and
component level. During normal operation of cross-referencing commands,
AutoCAD Electrical looks to the component for its settings information prior
to using the drawing settings. If the component has settings defined, those
are used. In the event that there are both component and drawing
cross-reference settings on the same drawing, the component settings are used
where applied and the drawing settings are used for the rest of the components.
Use the new Copy/Add Component Override tool to set display settings for
a specific component that are different than the drawing or use the new
Remove Component Override tool to remove component overrides so the
cross-referencing commands use the settings for the drawing.
Use the new Hide/Unhide Cross-Reference tool to change the visibility of
cross-references. In most cases the cross-referencing should be visible but there
are times when you may not want cross-referencing displayed on parent
symbols.
Wire Label Report
Use the new Wire Label report to list wire and cable labels that exist in your
drawing or project. The new preformatted wire label report is ready for export
and can be printed on any ASCII, Microsoft Excel, Access, CSV or
XML-compatible wire label printer. After the report is generated, you can still
edit the format or make changes to the data before exporting to your desired
file format.
Enhanced Drawing Audit Report
The Drawing Audit utility can be used to clean up certain problems that might
affect your design connectivity. The audit checks for wire gaps, bad wire
numbers or colors, zero length wires, wire number floaters, and visually verifies
What's New in 2007 Release | 19
Summary of Contents for 22505-051400-9000 - AutoCAD Electrical 2008
Page 1: ...AutoCAD Electrical 2008 User s Guide February 20 2007 ...
Page 4: ...1 2 3 4 5 6 7 8 9 10 ...
Page 106: ...94 ...
Page 228: ...216 ...
Page 242: ...HP W TERM_ VDC SPECIAL SPACINGFACTOR 0 5 HP WA D TERM_ 02 230 Chapter 5 PLC ...
Page 294: ...282 ...
Page 564: ...552 ...
Page 698: ...686 ...
Page 740: ...728 ...
Page 814: ...802 ...
Page 1032: ...1020 ...
Page 1134: ...1122 ...
Page 1168: ...1156 ...
Page 1177: ...Insert P ID Component Overview of pneumatic tools 1165 ...
Page 1198: ...1186 ...
Page 1269: ...AutoCAD Electrical Command In this chapter AutoCAD Electrical Commands 20 1257 ...
Page 1304: ...Z zip utility 82 1292 Index ...