printing and when saved to a file (the "top" portion is ig-
nored). If you put the report on the drawing, the report
justification is top right.
Available Fields
Component tag name
TAG
Conduit size (diameter)
SIZE
Manufacturer or vendor name (i.e. Siemens)
MFG
Catalog part number assignment
CAT
Optional assembly code value used in catalog lookup query to
get part number groups
ASSYCODE
Wire number
WIRENO
Wire layer
WIRELAY
Wire type description
WIREDESC
Wire gauge or diameter
WIREDIA
Type of spare or unused wires
SPARES
Count of spare or unused wires
SP/CNT
Description attribute values 1-2
DESC1-2
Entity handle number
HDL
Sheet - the %S value
SH
Length (calculated wire length)
LEN
818 | Chapter 14 Reports