scope of the report by filtering on certain location values (for example, report
for CAB1 items only), process only a subset of drawings, or include/exclude
certain categories of items. Each extracted panel component is listed as its
own line item. If it has a part number that results in subassembly part numbers,
or has been individually annotated with multi-BOM part numbers, each
additional part number is a line item right below the main line item.
NOTE
This report will not include panel terminals unless you check that option.
Nameplate report
This report is similar to the panel component report, but filters out all but
nameplate symbols.
Wire Connection report
Wire connection reports, extracted from the schematic wiring diagrams, can
be formatted and inserted next to panel footprint symbols as simple wiring
tables. AutoCAD Electrical extracts and formats a small report of wire
connection information for the selected components, referencing the wire
extract file. If your footprint symbols carry the AutoCAD Electrical X?TERMxx
attributes, AutoCAD Electrical reports their XYZ wire connection location.
The location is offset by the value defined in Panel Configuration dialog box.
Component Exception report
This report provides error checking between the schematics and panel layout
drawings. AutoCAD Electrical looks at the selected components, both schematic
and panel, looking for a match in the project. For each schematic component
selected, it tries to find a matching panel component based on tag, location,
and installation information. If a match is found, it compares catalog and
description information, looking for any discrepancies. AutoCAD Electrical
then looks at each selected panel component looking for a matching schematic
component in the same way.
Terminal Exception report
This report provides error checking between the schematic terminals and
panel layout terminals. AutoCAD Electrical looks at the selected terminals,
both schematic and panel, looking for a match in the project. For each
schematic terminal selected, it tries to find a matching panel terminal based
on tag, location, and installation information. If a match is found, it compares
catalog information, looking for any discrepancies. AutoCAD Electrical then
924 | Chapter 14 Reports
Summary of Contents for 22505-051400-9000 - AutoCAD Electrical 2008
Page 1: ...AutoCAD Electrical 2008 User s Guide February 20 2007 ...
Page 4: ...1 2 3 4 5 6 7 8 9 10 ...
Page 106: ...94 ...
Page 228: ...216 ...
Page 242: ...HP W TERM_ VDC SPECIAL SPACINGFACTOR 0 5 HP WA D TERM_ 02 230 Chapter 5 PLC ...
Page 294: ...282 ...
Page 564: ...552 ...
Page 698: ...686 ...
Page 740: ...728 ...
Page 814: ...802 ...
Page 1032: ...1020 ...
Page 1134: ...1122 ...
Page 1168: ...1156 ...
Page 1177: ...Insert P ID Component Overview of pneumatic tools 1165 ...
Page 1198: ...1186 ...
Page 1269: ...AutoCAD Electrical Command In this chapter AutoCAD Electrical Commands 20 1257 ...
Page 1304: ...Z zip utility 82 1292 Index ...