5
In the right pane, click the Single Line Graphics tab.
6
For Connector Graphics Block, select a block that matches the pipe connection type in the left
column.
NOTE
Block naming for unique connection graphics use Aecb_ConnectionType. However, many
connection types use the same Aecb_StandardPipe1LineGraphic graphics block.
7
Under Scaling for selected block, select Use Annotation Scale to scale the block to the annotation
plot size.
8
Select Override Scale, and enter values for coordinates X,Y, and Z.
NOTE
The annotation selections work together. The annotation scale determines whether the block
should be annotative. The override scale determines whether the block should be scaled beyond the
initial size of the annotation block. By default, blocks are scaled to the size of the nominal diameter.
For more information, see
on page 549.
Configuring the Straight Centerline Display of Elbows
You can control the centerline display of elbows and store results in the drawing.
To display the straight centerline
1
Enter
DisplayStraightCenterlines
.
2
Enter the domain:
c
(Conduit),
d
(Duct),
p
(Pipe), or
a
(All).
3
Enter
y
(Yes) to display straight centerlines on all applicable objects.
NOTE
Straight Centerline Display of Elbows
on page 261.
284 | Chapter 7 Drawing Piping Systems
Summary of Contents for 235B1-05A761-1301 - AutoCAD MEP 2010
Page 1: ...AutoCAD MEP 2010 User s Guide March 2009 ...
Page 22: ...4 ...
Page 86: ...68 ...
Page 146: ...128 ...
Page 180: ...162 ...
Page 242: ...Modifying the elevation of a duct 224 Chapter 6 Drawing HVAC Systems ...
Page 264: ...246 ...
Page 480: ...462 ...
Page 534: ...516 ...
Page 616: ...598 ...
Page 658: ...640 ...
Page 788: ...770 ...
Page 802: ...784 ...
Page 820: ...802 ...
Page 878: ...860 ...